HDC® II - J Series product photo Primary L

HDC® II - J Series

HDC® II filter cartridges are constructed of pure polypropylene, high area, pleated media. This new generation of HDC II filters, unlike the original HDC filters and other polypropylene pleated filters, has incorporated a proprietary concept into its medium construction: varying the fiber diameter continuously to produce a pore size distribution from coarse (upstream) to fine (downstream). This unique construction permits more contaminants to be trapped in the outer layers of the medium, thus substantially increasing dirt-holding capacity. The finer inner layers are essentially unchanged from those of the original HDC medium, thus maintaining the absolute rating of the filter.

Relative filter life studies, both in the laboratory and in the field, have shown that this new construction increases service life as much as four times compared to other filters of similar appearance.

Removal ratings range from 0.6 µm (micron) to 70.0 µm absolute. Refer to Bulletin HDC 700 for more detailed information.



Contact Us
* Required

Description

HDC® II filter cartridges are constructed of pure polypropylene, high area, pleated media. This new generation of HDC II filters, unlike the original HDC filters and other polypropylene pleated filters, has incorporated a proprietary concept into its medium construction: varying the fiber diameter continuously to produce a pore size distribution from coarse (upstream) to fine (downstream). This unique construction permits more contaminants to be trapped in the outer layers of the medium, thus substantially increasing dirt-holding capacity. The finer inner layers are essentially unchanged from those of the original HDC medium, thus maintaining the absolute rating of the filter.

Relative filter life studies, both in the laboratory and in the field, have shown that this new construction increases service life as much as four times compared to other filters of similar appearance.

Removal ratings range from 0.6 µm (micron) to 70.0 µm absolute. Refer to Bulletin HDC 700 for more detailed information.

Specifications

 

Operating Characteristics

The recommended maximum pressure differential for the HDC “J” Series filters is 75 psid up to 140°F (60°C) and 45 psid up to 180°F (82°C) for UNI CAP filters, and 80 psid up to 122°F (50°C) and 60 psid up to 176°F (80°C) for AB style filters.

 

Warning: Using these filters for filtration at higher pressures or temperatures than recommended, or with fluids incompatible with polypropylene, can result in property damage or personal injury and contaminated filtrate.

Sizes

HDC II "J" Series media are available in the UNI CAP configuration. UNI CAP series pleated elements are manufactured as 2 1/2" OD by 10, 20, 30, and 40 inch long filter cartridges. Elastomeric gaskets are attached to each end cap.

 

Sanitary (AB Style) elements are 2 3/4" OD by 10" single open-ended constructions with an O-ring piston seal at the open end. AB style elements are also available in 20, 30, and 40 inch lengths.


Table I: Liquid Service
 
Cartridge Grade

Liquid Removal1 Rating in Microns (µm)
at % Efficiency

Aqueous Clean Pressure
Drop2 Per 10” Module (PSI/GPM)

Typical Flow Rate
Per 10" Module (GPM)
       
  90% 99.98% AB Style UNI CAP Style 1-2
           
J006 - <1.0* 1.25 1.55 2-3
           
J012 <1.0* 1.2 0.22 0.31 2-3
           
J025 <1.0* 2.5 0.15 0.16 2-3
           
J045 1.2 4.5 0.11 0.12 2-3
           
J060 3.0 6.0 0.08 0.08 2-3
           
J100 5.4 10.0 0.06 0.06 3-5
           
J200 10.0 20.0 0.03 0.03 3-5
           
J400 22.0 40.0 0.02 0.02 5-8
           
J700 35

70.0

0.01 0.01 8-10
 
* Extrapolated value.

1 The test procedure used for liquid service rating is an adaptation of ANSI B93.31 - 1973, modified to determine the micron size above which particles are quantitatively removed.

2 Pressure drop in PSI per GPM water for a single 10" module. Multiply this value by the required flow to determine the total aqueous pressure drop. Next, for fluids other than water, multiply by viscosity in centipoise. If this calculated pressure drop is excessive, then divide this value by the number of 10" modules required to reduce this pressure drop to an acceptable level.


Features and Benefits

 

 
FeaturesAdvantagesBenefits
     
Absolute Rated Medium 99.98% removal efficiency Consistent, reliable filtration
     
Tapered Pore Medium Prefilter layers Longer service life by factors up to 4 times
     
Fixed Pore Structure No solids unloading or media migration No contamination of filtered process fluid
     
Polypropylene Medium with No Surfactants or Binders Negligible level of extractables Wide chemical compatibility
 

 

Housing Information

Housings are available in polypropylene, other polymers, carbon steel,stainless steel. Refer to brochure SUM 200 for further details.

Applications

 
HDC II filters are specifically designed for use in applications where economy and reliability are critical. All materials of construction are FDA listed for direct food contact, and all components have been tested according to the USP Class VI biological tests for plastics at 250°F (121°C).

Representative applications include:

  • General Service: rinse water, reverse osmosis system pre-filtration, water–prior to and/or after demineralization.
  • General Process Industries: electroplating solutions, metal etching solutions, audio and video tape coatings, automotive paints, can coatings, coil coatings, computer tape and disc coatings, photographic film manufacturing and processing.
  • Chemical/Petrochemical Industries: amines for gas scrubbing, monomers, polymers, glycols, herbicides and pesticides, liquid catalysts, product polishing, photoresists, acids, bases, solvents, deep well disposal fluids.
  • Film and Fiber Industries: monomers, quench water, slurry additives, delusterants, slip agents, D.I. water, solvents, spin finishes, aqueous salt solutions.
  • Power Generation Industries: makeup water, laundry drain wastewater, steam generator blowdown prefilters.
  • Pharmaceutical Industry: parenterals, ophthalmics, oral medications.
  • Biological Industry: serum and serum fractions, tissue culture media, vaccine preparations, microbiological growth media, media makeup water, diagnostic sera.
  • Cosmetics: toiletries, aftershaves, perfumes, oils, lotions, creams, ointments, shampoos, body rinses, mouthwashes.
  • Fermentation Industries: liquid growth media, makeup water, intermediates, final liquid products, additives, exhaust gas, prefiltration.
  • Food and Beverage Industries: potable liquids, wine, beer, soft drinks, flavors, storage tank/reactor vents, corn syrup, edible oils.
  • Electronic Industries: photoresists, acids, bases, solvents, etchant gases, D.I. water prefiltration.

Type

Filter Cartridges

Ordering Information

Ordering Information/Part Numbers

HDC II “J” Series Element Part Number:
UNI CAP Element PUY

Sanitary (AB) Style Element AB      

 
Code
Cartridge Lengths
   
1 10''
   
2 20''
   
3 30''
   
4 40''
 

 

 
Code
Grade: 99.98%
Removal Rating (µm)
   
J006 <1.0*
   
J012 1.2
   
J025 2.5
   
J045 4.5
   
J060 6.0
   
J100 10
   
J200 20
   
J400 40
   
J700 70
 

 

 
Code
 

End Fittings

   
 O-Ring Fitting I.D. (In.)O-Ring Replacement Size
     
3 1 1/4 -222 (Flat end)
     
7 1 1/2 -226 (Finned end & bayonet lock)
     
8 1 1/4 -222 (Finned end)
 

 

 
Code
Application Option
   
Omit Other
   
P Pharmaceutical
 

 

 
Code
Gasket Option
   
H13 Buna N
   
H fluorocarbon elastomer A*
   
J Ethylene Propylene (Standard)
 

 

 
Code
O-Ring Option
   
H4 Silicone (Standard)
   
H fluorocarbon elastomer A*
   
J Ethylene Propylene
 

* Trademark of E.I. du Pont de Nemours and Co.

Reviews

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.