Pall Pro-Tec® PF30S Filter for Pulmonary Function Testing product photo Primary L

Pall Pro-Tec® PF30S Filter for Pulmonary Function Testing

A Pall quality product

  • Manufactured under approved standards
  • Performance tested in independent laboratories 1,5,7,9
  • Clinically proven safety 2,3,4

High efficency low resistance filtration medium

  • The PF30S prevents the passage of aerosolised micro-droplets
  • Reducing the contamination level of pneumotachographs, valves and machinery 2,5
  • Protecting patients against cross-contamination 2,3,5
  • Clinical studies show that the PF30S has no clinically significant effect on the Pulmonary instrument of "Viasys" Spirometer manufactured by Viasys Healthcare GMBH, "Viasys" Pulmonary Function Lab manufactured by VIASYS Respiratory Care Inc.. "Viasys" Vmax Encore Series Pulmonary/Metabolic Systems manufactured by VIASYS Respiratory Care Inc. on the most static and dynamic pulmonary function test parameters, like VC, FVC, FEF1, FEF25-75%, FEF50%, PEFR, RV, FRC, TLC, TLCO, KCO, VA 2,8,10
  • Even on pediatric patients, no significant changes can be found 4

Clear transparent housing

  • Allows for easy monitoring of gross contamination with mucus and patient secretions
  • Clean and hygienic appearance for patient comfort and safety
  • Free of PVC and natural rubber latex
  • May be used as a mouth piece

Bi-Directional housing and media design

  • The PF30S can be used on test protocols that include in-and-expiratory breathing maneuvers 2
  • Resistance does not change during use 6

Small volume (40mL)

  • Prevents deviations in test results due to the patient's compensation of additional deadspace
  • Minimal influence on volume related measurements 2

Cost Efficient

  • The PF30S has been shown to reduce labor and material cost 3

Consistently high quality

  • Well controlled manufacturing process ensures dimensional consistency
    • Tight connector fitting prevents leakage during diffusion tests
      6
    • Smooth design reduces turbulent flow and gives very low resistance 2,3
  • 100% integrity tested

References

  1. Guimond VN et al. Canadian J Resp Ther 1990; 26(3):9
  2. Strauss R et al. Pneumologie 1993;47:626030
  3. Billing E. Br Med J 1991;303:
  4. Gruper W et al. Pneumologie 1992;46:573-5
  5. Fürber WU. Expertise 1990
  6. Johns DP. Chest 1994;107:1045-8
  7. Kirk YL. Journal of Hospital Infection 1992;20:193-8
  8. Rust M. Atems-und Lungenkrankheiten 1989:211
  9. Miorini T. Expertise 1991 10. Miralda R. XVII dia de pneumológia 1999


Contact Us
* Required

Description

A Pall quality product

  • Manufactured under approved standards
  • Performance tested in independent laboratories 1,5,7,9
  • Clinically proven safety 2,3,4

High efficency low resistance filtration medium

  • The PF30S prevents the passage of aerosolised micro-droplets
  • Reducing the contamination level of pneumotachographs, valves and machinery 2,5
  • Protecting patients against cross-contamination 2,3,5
  • Clinical studies show that the PF30S has no clinically significant effect on the Pulmonary instrument of "Viasys" Spirometer manufactured by Viasys Healthcare GMBH, "Viasys" Pulmonary Function Lab manufactured by VIASYS Respiratory Care Inc.. "Viasys" Vmax Encore Series Pulmonary/Metabolic Systems manufactured by VIASYS Respiratory Care Inc. on the most static and dynamic pulmonary function test parameters, like VC, FVC, FEF1, FEF25-75%, FEF50%, PEFR, RV, FRC, TLC, TLCO, KCO, VA 2,8,10
  • Even on pediatric patients, no significant changes can be found 4

Clear transparent housing

  • Allows for easy monitoring of gross contamination with mucus and patient secretions
  • Clean and hygienic appearance for patient comfort and safety
  • Free of PVC and natural rubber latex
  • May be used as a mouth piece

Bi-Directional housing and media design

  • The PF30S can be used on test protocols that include in-and-expiratory breathing maneuvers 2
  • Resistance does not change during use 6

Small volume (40mL)

  • Prevents deviations in test results due to the patient's compensation of additional deadspace
  • Minimal influence on volume related measurements 2

Cost Efficient

  • The PF30S has been shown to reduce labor and material cost 3

Consistently high quality

  • Well controlled manufacturing process ensures dimensional consistency
    • Tight connector fitting prevents leakage during diffusion tests
      6
    • Smooth design reduces turbulent flow and gives very low resistance 2,3
  • 100% integrity tested

References

  1. Guimond VN et al. Canadian J Resp Ther 1990; 26(3):9
  2. Strauss R et al. Pneumologie 1993;47:626030
  3. Billing E. Br Med J 1991;303:
  4. Gruper W et al. Pneumologie 1992;46:573-5
  5. Fürber WU. Expertise 1990
  6. Johns DP. Chest 1994;107:1045-8
  7. Kirk YL. Journal of Hospital Infection 1992;20:193-8
  8. Rust M. Atems-und Lungenkrankheiten 1989:211
  9. Miorini T. Expertise 1991 10. Miralda R. XVII dia de pneumológia 1999

Type

Respiratory and Anesthesia Products

Use

Testing

Ordering Information


 
 
 
Pall Pro-Tec PF30S Filter for Pulmonary Function Testing
Part Number Description Pkg
PF30S Pro-Tec PF30S Filter with 30mm Ports 25/pkg
PF30SG Pro-Tec PF30S Filter with 30mm Ports 250/pkg
PF30SJE Pro-Tec PF30S with modified 30mm port, for use with pulmonary function equipment 25/pkg
PS30SJG Pro-Tec PF30S with modified 30mm port, for use with pulmonary function equipment 250/pkg
MPE1E Mouthpiece for pulmonary function testing 1/pkg
PF30-Kit1 Pall PF30S Filter, Preattached Pall MPE1 Soft Plastic Mouth Piece and Nose Clip 25 per case
PF30-Kit2 Pall PF30SJE Filter and Preattached Hard Plastic Mouth Piece 25 per case
PF30-Kit3 Pall PF30SJE Filter, Preattached Pall MPE1 Soft Plastic Mouth Piece and Nose Clip 25 per case
 

Reviews

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.