SepraSol™ Series Liquid/Gas Coalescer Housings product photo Primary L

SepraSol™ Series Liquid/Gas Coalescer Housings

Description

Pall SepraSol™ coalescer housings provide a range of standard vessels to complement the Pall SepraSol and SepraSol Plus liquid/gas coalescers, which are used to remove liquid and solids from a wide range of gas streams found in process industries including refinery, natural gas conditioning, chemical production, and power generation. These housings are available for both the single open-ended and double openended SepraSol coalescer designs and the larger SepraSol Plus coalescer designs. Standard sizes accommodate from 1 to 70 coalescers.

Key Benefits

Combination of these housings with Pall SepraSol elements provide many benefits, including:

  • Lower operating costs
  • Lower capital costs (minimized envelope size)
  • Lower weight
  • Maximum flexibility

All Pall SepraSol products contain a patented oleophobic/hydrophobic treatment that enables them to:

  • Drain liquids more quickly and handle higher liquid loads
  • Recover quickly from slugs and upsets
  • Require fewer elements resulting in the smallest vessel for the separation efficiency provided


Contact Us
* Required

Description

Description

Pall SepraSol™ coalescer housings provide a range of standard vessels to complement the Pall SepraSol and SepraSol Plus liquid/gas coalescers, which are used to remove liquid and solids from a wide range of gas streams found in process industries including refinery, natural gas conditioning, chemical production, and power generation. These housings are available for both the single open-ended and double openended SepraSol coalescer designs and the larger SepraSol Plus coalescer designs. Standard sizes accommodate from 1 to 70 coalescers.

Key Benefits

Combination of these housings with Pall SepraSol elements provide many benefits, including:

  • Lower operating costs
  • Lower capital costs (minimized envelope size)
  • Lower weight
  • Maximum flexibility

All Pall SepraSol products contain a patented oleophobic/hydrophobic treatment that enables them to:

  • Drain liquids more quickly and handle higher liquid loads
  • Recover quickly from slugs and upsets
  • Require fewer elements resulting in the smallest vessel for the separation efficiency provided

Specifications

 

Specifications

  • Housings are designed and stamped in accordance with ASME/ANSI BPVC Section VIII
  • Design ratings - three standard design classifications are available:
    Low Pressure: ANSI - 150 lb., 285 psig
    (19.65 bar) @ 100°F (37.8°C)
    Medium Pressure: ANSI - 300 lb., 740 psig
    (51.02 bar) @ 100°F (37.8°C)
    High Pressure: ANSI - 600 lb., 1480 psig
    (102.04 bar) @ 100°F (37.8°C)
  • Carbon steel construction
  • Vent and drain connections, as well as pressure tap ports provided
  • Automatic control options available
  • External paint

 

Element Sealing Mechanism

 

Pall SepraSol liquid/gas coalescer seals are designed to prevent contamination bypass. The single open-ended coalescers are sealed with a single outer O-ring made of material compatible with petroleum products. The double open-ended coalescer is sealed by gaskets and held in place by a tie-rod and seal nut.

 

Filter Element Selection

 

The Pall SepraSol and SepraSol Plus liquid/gas coalescer elements are listed in Table 1. Please refer to Element Data Sheets GAS-4102d, GDS100 or GDS122 for additional information.

 

Operating Characteristics

 

All types and grades of SepraSol elements are rated to withstand a maximum temperature of 180°F (82.22°C) for the removal of non- aqueous liquids and 140°F (60.00°C) for the removal of aqueous liquids. All elements have a recommended changeout pressure of 15 psid.

 

Table 1: Pall Coalescer Elements for Use in SepraSol™ Housings

 

 
Part NumberDescriptionOuter Diameter (in/mm)Length (in/mm)
       
CC3LGA7H13 SepraSol coalescer (single open-ended) 2 3⁄4 / 69.9 30 / 762
       
CC3LGB7H13 SepraSol coalescer (single open-ended)
Amine/ammonia compatible
2 3⁄4 / 69.9 30 / 762
       
CC3LGO2H13 SepraSol coalescer (double open-ended) 2 3⁄4 / 69.9 30 / 762
       
CS604LGH13 SepraSol Plus coalescer (single open ended) 6 / 152.4 40 / 1016
       
CS604LGBH13 SepraSol Plus coalescer (single open ended)
Amine /ammonia compatible
6 / 152.4 40 / 1016
 

Type

Housings, Vessels, or Assemblies

Ordering Information

Part Numbers/Ordering Information

 LG    F

 
Number of
Elements
Housing
Diameter (in.)
Connection
Options (in.)
     
1 06 02, 03
     
2 08 03, 04
     
3 10 03, 04
     
5 12 04, 06
     
9 16 06, 08
     
14 20 06, 08, 10
     
19 24 06, 08, 10, 12
     
43 30 08, 10, 12, 14
     
70 36 12, 14, 16, 18
 
* Additional sizes, pressure and connection options are available as specials.

** Note: Standard housings for “single open-ended” cartridges only available in low pressure option.
 
Code  End Option
   
Blank Single open-ended
SepraSol Coalescer
   
D Double open-ended
SepraSol Coalescer
   
H Single open ended
SepraSol Plus Coalescer
 
 
Code  Design Pressure Ratings
   
1-285 ANSI-150 psig (10.34 bar),
285 psig (19.65 bar) at
100°F (37.78°C)
   
3-740 ANSI-300 psig (20.68 bar),
740 psig (51.02 bar) at
100°F (37.78°C)
   
6-1480 ANSI-600 psig (41.37 bar),
1480 psig (102.04 bar) at
100°F (37.78°C)
 