CPF System® Polymer Candle Filter Systems product photo Primary L

CPF® System Polymer Candle Filter Systems

The CPF Process Reduces Downtime

All Fluid Dynamics CPF Systems, both Model 100 and 200 series, operate using parallel filter circuits that permit continuous, uninterrupted process filtration.

In operation, one filter housing/element assembly is on-stream until a predetermined differential pressure is reached(Fig. 1). Then, by operating the two handwheels, the spool valves are repositioned, in proper sequence, to progressively close off flow to the housing containing the “dirty” filter elements, and divert flow to the off-stream housing containing the clean filter elements (Fig. 2). Vent valves are incorporated to purge the air during the filling of the off-stream housing to maintain balanced system pressure and prevent entrainment of air in the process stream. Upon completion of the changeover sequence (Fig. 3), the “dirty” housing/element assembly is removed and replaced with a clean assembly.



The CPF Advantage Simple and Field-Serviceable

Our CPF systems are designed for ease of operation and maintenance, and they eliminate the need for breaking heating connections and disassembling interconnecting piping during filter housing changes. As a result, CPF housing changes can be completed in less than 30 minutes. Furthermore, all components in our CPF systems are field serviceable by trained technicians.

Custom systems may be designed for specific applications requiring enhanced flow properties.

All CPF systems are designed to offer safe, dependable and uniform heating.

Model 100 Series CPF Systems

Our CPF Model 100 series are standard horizontal systems with a compact design, ideal for applications with low flow rates and/or limited space. The valves are operated manually and can provide a smooth, “bumpless” changeover, with no disruption to the down-stream process.


Model 200 Series CPF Systems

Our CPF Model 200 series are large, vertical systems designed for applications with special requirements and/or high flow rates. They are available configured for manual operation, or in fully automated, computer-controlled designs. With the complete computer-controlled valve package, the Model 200 ensures consistently smooth, “bumpless” changeovers, and significantly reduces operator error and safety risks

In Model 200 CPF systems, the filter housing and heat exchanger together form a simple, self-aligning mechanism that enables the removal and installation of the filter housing in less than 30 minutes.



Contact Us
* Required

Description

The CPF Process Reduces Downtime

All Fluid Dynamics CPF Systems, both Model 100 and 200 series, operate using parallel filter circuits that permit continuous, uninterrupted process filtration.

In operation, one filter housing/element assembly is on-stream until a predetermined differential pressure is reached(Fig. 1). Then, by operating the two handwheels, the spool valves are repositioned, in proper sequence, to progressively close off flow to the housing containing the “dirty” filter elements, and divert flow to the off-stream housing containing the clean filter elements (Fig. 2). Vent valves are incorporated to purge the air during the filling of the off-stream housing to maintain balanced system pressure and prevent entrainment of air in the process stream. Upon completion of the changeover sequence (Fig. 3), the “dirty” housing/element assembly is removed and replaced with a clean assembly.



The CPF Advantage Simple and Field-Serviceable

Our CPF systems are designed for ease of operation and maintenance, and they eliminate the need for breaking heating connections and disassembling interconnecting piping during filter housing changes. As a result, CPF housing changes can be completed in less than 30 minutes. Furthermore, all components in our CPF systems are field serviceable by trained technicians.

Custom systems may be designed for specific applications requiring enhanced flow properties.

All CPF systems are designed to offer safe, dependable and uniform heating.

Model 100 Series CPF Systems

Our CPF Model 100 series are standard horizontal systems with a compact design, ideal for applications with low flow rates and/or limited space. The valves are operated manually and can provide a smooth, “bumpless” changeover, with no disruption to the down-stream process.


Model 200 Series CPF Systems

Our CPF Model 200 series are large, vertical systems designed for applications with special requirements and/or high flow rates. They are available configured for manual operation, or in fully automated, computer-controlled designs. With the complete computer-controlled valve package, the Model 200 ensures consistently smooth, “bumpless” changeovers, and significantly reduces operator error and safety risks

In Model 200 CPF systems, the filter housing and heat exchanger together form a simple, self-aligning mechanism that enables the removal and installation of the filter housing in less than 30 minutes.

Specifications

Model 100 Series CPF Systems

MODEL 100 DIMENSIONS (mm)

 
  110 120 130 135 140
A 324 334 324 324 508
B 339 345 355 355 424
C 362 381 381 381 546
D 635 762 762 762 775
E 356 356 356 356 356
F 610 826 826 1207 1092
 

Design Criteria

System Pressure: to 345 bar
System Temperature: to 330˚ C
Differential Pressure: to 210 bar depending on element configuration
Heating: liquid, vapor or electric

Connections

Process: Butt weld standard. Clamp or flange style available
Heating: Butt weld standard. Flange style available

Materials of Construction

Valve Bodies: Type 304 stainless steel
Filter Housings: Type 17-4 PH stainless steel
Seats & Gaskets: Aluminum
Packings: RYTON® standard (others available)
Heat Exchanger: Carbon steel, double wall construction (liquid or vapor) Aluminum (electric)
Insulation: High temperature fiberglass blanket with non-stick outer covering standard (stainless steel cover available)

Model 200 Series CPF Systems

Design Criteria

System Pressure: to 345 bar
System Temperature: : to 330˚C
Differential Pressure: to 210 bar depending on element configuration
Heating: liquid, vapor or electric

Connections

Process: Butt weld standard Clamp or flange style available
Heating: Butt weld standard Flange style available Complete heating manifolds available

Materials of Construction

Valve Bodies: Type 17-4 or 304 stainless steel
Filter Housings: Type 17-4 or 304 stainless steel
Seats: Aluminum
Housing Seals: Stainless steel o-ring
Packings: Ryton standard (others available)
Heat Exchanger: Carbon steel, double wall construction (liquid or vapor) aluminum (electric)
Insulation:
(option)
High temperature fiberglass blanket with non-stick outer covering stainless steel cover available
The heat exchanger and the filter housings are designed to ASME code and may be "U" stamped upon request.

Performance


Model 100 CPFs

 
  System Filter Area Valve Bore
A 110 0.5 m2 27 mm
B 120 1.1 m2 27 mm
C 130 1.1 m2 38 mm
D 135 2.2 m2 38 mm
E 140 3.5 m2 58 mm
 

Model 200 CPFs

 
  System Filter Area Valve Bore
A 230 - 10940 11.5 m2 58 mm
B 240 - 13250 20.0 m2 80 mm
C 250 - 18756 45.0 m2 103 mm
 

Type

Systems