Pasteurizer Replacement Filter Family product photo Primary L

Pasteurizer Replacement Filter Family

For "Sterile" Filtration of Beer

Pasteurizer replacement filter cartridges are hydrophilic membrane filters designed for reliable retention of spoilage microorganisms in the filtration of beer in the CFS NEO system or standard housings.

Description

The Pasteurizer Replacement filter cartridge family was developed and validated for removal of beer spoilage microorganisms in the CFS NEO system or standard housings.

The Pasteurizer Replacement filter cartridges are constructed from one layer of polyethersulfone (PES) membrane in a laid-over-pleat configuration. The single open ended (SOE) configuration is designed to fit into the sanitary housings on the CFS NEO system and standard housings to ensure effective microbial reduction and assembly integrity.

Pasteurizer Replacement filter cartridges are suitable for exposure to repeated hot water sanitization and in situ steam sterilization cycles for longer service life in the CFS NEO system. The optimized support and drainage materials, provide increased mechanical strength during operation, repeated hot water, chemical and steam sanitization and thus, high throughput.

 
Features Benefits
Cartridges resistant to numerous sanitization cycles
  • Process reliability
  • Economical operation
  • Consistent filtrate quality
Hydrophilic membranes
  • Easy to wet and integrity test
  • Microbial stabilization of beer
Validated with beer spoilage microorganisms
  • Brand protection
  • Increased process safety
Individually serialized cartridges
  • Full traceability
Integrity testable
  • Brand protection
  • Documentation for quality records
 

Quality

  • Cartridges are produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System
  • All final filters are 100% integrity tested before manufacturing release

Food Contact Compliance

Please refer to the Pall website https://pall.com/en/food-beverage/compliance-and-safety.html for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.



Contact Us
* Required

Datasheet

Download: English

For "Sterile" Filtration of Beer

Pasteurizer replacement filter cartridges are hydrophilic membrane filters designed for reliable retention of spoilage microorganisms in the filtration of beer in the CFS NEO system or standard housings.

Description

The Pasteurizer Replacement filter cartridge family was developed and validated for removal of beer spoilage microorganisms in the CFS NEO system or standard housings.

The Pasteurizer Replacement filter cartridges are constructed from one layer of polyethersulfone (PES) membrane in a laid-over-pleat configuration. The single open ended (SOE) configuration is designed to fit into the sanitary housings on the CFS NEO system and standard housings to ensure effective microbial reduction and assembly integrity.

Pasteurizer Replacement filter cartridges are suitable for exposure to repeated hot water sanitization and in situ steam sterilization cycles for longer service life in the CFS NEO system. The optimized support and drainage materials, provide increased mechanical strength during operation, repeated hot water, chemical and steam sanitization and thus, high throughput.

 
Features Benefits
Cartridges resistant to numerous sanitization cycles
  • Process reliability
  • Economical operation
  • Consistent filtrate quality
Hydrophilic membranes
  • Easy to wet and integrity test
  • Microbial stabilization of beer
Validated with beer spoilage microorganisms
  • Brand protection
  • Increased process safety
Individually serialized cartridges
  • Full traceability
Integrity testable
  • Brand protection
  • Documentation for quality records
 

Quality

  • Cartridges are produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System
  • All final filters are 100% integrity tested before manufacturing release

Food Contact Compliance

Please refer to the Pall website https://pall.com/en/food-beverage/compliance-and-safety.html for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

Materials of Construction

 
Component Description
Filter Media* Polyethersulfone (Hydrophilic)
Support and Drainage Polypropylene
Core, Cage, End Cap and Fin End Polypropylene
Adaptor Polypropylene with internal stainless steel reinforcing o-ring
O-ring Seal Ethylene propylene rubber or Silicone elastomer
 
* Each 10” module contains 0.75m² (8.0 ft²) of effective filtration area.

CFS NEO System

Test Organism Log Reduction Value (LRV)

 
Final Membrane
Filters
Serratia marcescens
(ATCC 14756)
Lactobacillus brevis
in beer
Pediococcus damnosus
in beer
AB+PAREQII+W+ 8 8 7
 



Figure 1: Titer Reduction (TR) definition


TR = Total number of organisms influent to the 10” filter
Number of colonies recorded downstream


Technical Information

Operating Characteristics in Compatible Fluids1

 
Maximum Differential Pressure Operating Temperature
4.0 bard (58.0 psid) (forward pressure) 80 °C (176 °F)
1.0 bard (14.5 psid) (reverse pressure) 40 °C (104 °F)
 
1 Compatible fluids are defined as those which do not swell, soften or attack any of the filter componants.

Chemical Cleaning (static soak conditions)2

 
Media Temperature Cumulative Exposure
Caustic 2% 50 °C (122 °F) 400 hours
Caustic 2% 80 °C (176 °F) 200 hours
 
2 Measured under laboratory test conditions. The actual cumulative time depends on the process conditions.

Pressure Drop3

 
Code Value
PAREQII 42.5 l/min @ 100 mbar (7.6 US gal @1psi)
 
3 Typical initial clean media differential pressure (dP) per 254 mm (10”) cartridge for water at 20°C (68°F), viscosity 1 centipoise. For 508, 762 and 1016 mm configurations, divide the differential pressure by 2, 3 and 4 respectively.

Sterilization and Sanitization

 
Media Temperature Cumulative Exposure
Steam 125 °C (257 °F) 125 x 20 min cycles
Hot water 90 °C (194 °F) 200 x 30 min cycles
Peracetic acid (PAA), 325 ppm
PPA (1275 ppm H2O2 to give 1600
ppm of total peroxides)
Ambient 2000 hours
 
*Measured under laboratory test conditions. The actual cumulative time depends on the process conditions. For applications requiring sterilization or sanitization Pall recommends the use of Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Contact Pall for recommended procedures.
Cartridge / System

Cartridge Part Number


AB [Table 1] PAREQII [Table 2] W [Table 3]

This is a guide to the Part Numbering structure only. For specific options, please contact Pall.


Table 1: Nominal Length

 
Code Description
1 254 mm (10”)
2 508 mm (20”)
3 762 mm (30”)
4* 1016 mm (40”)
 

*40” filter elements are suitable for use in a CFS system

Table 2: Adaptor

 
Code Description
3 SOE – single open end with flat closed end and external 222 O-rings
7 SOE – single open end with fin end, 2 locking tabs and external 226 O-rings
8 SOE – single open end with fin end and external 222 O-rings
28 SOE – single open end with fin end, 3 locking tabs and external 222 O-rings
 

Table 3: O-Ring Seal Material

 
Code Description
H4 Silicone Elastomer
J Silicone Elastomer J Ethylene Propylene Rubber
 

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.