Description
For High Volume Depth Filtration
SUPRApak Multi-Stack Series-SA housings are designed for use with SUPRApak L filter modules. They revolutionize high volume depth filtration applications in the food and beverage industry, providing a cost-effective alternative to classical sheet filtration.Features | Benefits |
Closed filtration system | Increased process safety and product quality; minimized product losses, product contamination risk and personnel exposure to process fluids |
Installation package with standard accessories | Turn-key installation allows quick integration into existing system |
Compact design with high filtration area | Extremely high throughput at low investment cost |
Drainable, low holdup volume assembly | Higher product yield; minimized cleaning costs |
High quality internal surface finish, sanitary and crevice-free design | Enhanced cleanability |
Flexible modular design | Production volumes can be matched to equipment capacity by using different housing domes |
External tensioning devices | Provides secure operation without bypass |
Dual inlet connections | Minimizes product mixing zones |
Simple, quick installation and servicing | Reduced labor, maintenance and downtime costs |
Filter module lifting device available on request | Eases filter installation and removal |
Specifications
SUPRApak Multi-Stack filtration units provide a closed system approach to high capacity depth filtration, maximizing product protection and minimizing product losses. Lower cost of ownership is achieved due to higher throughput, yield improvement, and reduced handling, cleaning, maintenance and downtime costs, when compared to sheet filtration.
SUPRApak Multi-Stack technology is ideal for use in high volume beer, sweetener, enzyme, gelatin, yeast extract, and other food and beverage applications.
SUPRApak Multi-Stack Series-SA units provide a complete installation package for quick integration into an existing system. They hold from 16 to 24 SUPRApak L modules, representing up to approximately 240 m2 (2583 ft2) of filtration area in a very compact and low hold-up volume design. They are available in single dome design.
1 Maximum design pressure and temperature ratings are vessel ratings only. Safe operation will also depend on filter module and housing gasket use. EPDM assembly seals restrict continuous operating temperature to 130 ºC (266 ºF). For details on module temperature limitations, please refer to SUPRApak module literature.
SUPRApak Multi-Stack Series-SA systems are supplied with standard accessories. Riser pipes are additionally supplied for applications requiring minimized mixing zones. Please consult Pall.
5 Pall Corporation reserves the right to make dimensional modifications at any time, maintaining the same fit, form, and function. Please request a general arrangement drawing if exact dimensions are required.
Dimensional information of Filter System, SARP (with Riser Pipe)
Dimensional information of Filter System, SA (without Riser Pipe)
SUPRApak Multi-Stack technology is ideal for use in high volume beer, sweetener, enzyme, gelatin, yeast extract, and other food and beverage applications.
SUPRApak Multi-Stack Series-SA units provide a complete installation package for quick integration into an existing system. They hold from 16 to 24 SUPRApak L modules, representing up to approximately 240 m2 (2583 ft2) of filtration area in a very compact and low hold-up volume design. They are available in single dome design.
Minimum/Maximum Design Pressure1, 2 |
Liquids and Gases: -1 to 6 barg (-14.5 to 87 psig) | |
Minimum/Maximum Operating Temperature1 |
-10 to 150 °C (14 to 302 °F) | |
Materials of Construction | Wetted parts 1.4404 (AISI 316L stainless steel) | |
Sealing Materials3 | EPDM elastomer | |
Internal Surface Finish | Housing | ≤ 0.8 micrometers Ra (≤ 32 Ra microinches), electropolished |
Piping | ≤ 0.8 micrometers Ra (≤ 32 Ra microinches) | |
Internal Welds | Housing | Dressed and blended to provide uniform ripple- and crevice-free surface to ≤ 0.8 micrometers Ra (≤ 32 Ra microinches), electropolished |
Piping | Weld finish is as welded, with a uniform, crevice-free profile. ≤ 1.6 micrometers Ra (≤ 63 Ra microinches), pickled and passivated or bright annealed |
|
Connections | Inlet/Outlet | DN 100 (DIN 11851) 4 inch ISO 2852 clamp coupling compatible adaptors available by specific order |
Feed Fluid Vent | DN 25 (DIN 11850) pipe | |
Filtrate Vent | DN 15 (DIN 11850) pipe | |
Drains - Piping Drain - Safety |
DN 25 (DIN 11850) pipe DN 50 (DIN 11850) pipe |
|
Filter Module Compatibility4 | SUPRApak L series modules | |
1 Maximum design pressure and temperature ratings are vessel ratings only. Safe operation will also depend on filter module and housing gasket use. EPDM assembly seals restrict continuous operating temperature to 130 ºC (266 ºF). For details on module temperature limitations, please refer to SUPRApak module literature.
2 Design satisfies EC Pressure Equipment Directive (PED) 97/23/EC (Fluid Group 1, Category IV, Module G). Pressure rating is suitable for hazardous liquids or gases.
3 Seal materials meet requirements for food contact use as detailed in FDA 21 CFR Section 177.2600, and EC Regulation 1935/2004, including BfR XV and XXI. Please contact Pall for additional options.
4 Refer to Pall Food and Beverage SUPRApak module literature for additional guidelines on use.
SUPRApak Multi-Stack Series-SA systems are supplied with standard accessories. Riser pipes are additionally supplied for applications requiring minimized mixing zones. Please consult Pall.
Nominal Dimensions in mm (inches)
For specific dimensions, please contact Pall5.MS-400 | MS-500 | MS-600 | |
A | 3500 (137.8) | 4000 (157.5) | 4500 (177.2) |
B | 2375 (93.5) | 2630 (103.5) | 2880 (113.4) |
C6 | 616 (24.3) | 616 (24.3) | 616 (24.3) |
D6 | 500 (19.7) | 500 (19.7) | 500 (19.7) |
E7 | 1400 (55.1) | 1400 (55.1) | 1400 (55.1) |
F7 | 1210 (47.6) | 1210 (47.6) | 1210 (47.6) |
G | 1050 (41.3) | 1050 (41.3) | 1050 (41.3) |
H | 2140 (84.3) | 2393 (94.2) | 2646 (104.2) |
I 7 | 1110 (43.7) | 1110 (43.7) | 1110 (43.7) |
5 Pall Corporation reserves the right to make dimensional modifications at any time, maintaining the same fit, form, and function. Please request a general arrangement drawing if exact dimensions are required.
6 Adjustable (leg height adjustment)
7 Indicated dimensions are for installations requiring DIN connections. For installations requiring clamp coupling connections, an optional DIN to clamp coupling adaptor is additionally available. See Optional Accessories. If adaptors are added to the inlet and outlet connections, add 63.3 mm (2.5 in) for each adaptor to the pipeline length.
Volume and Weight8
MS-400 | MS-500 | MS-600 | ||
Volume L (US gal) | SA | 1060 (280) | 1275 (337) | 1490 (394) |
SARP | 1090 (288) | 1305 (345) | 1520 (402) | |
Weight kg (lbs) | SA | 810 (1786) | 840 (1852) | 870 (1918) |
SARP | 840 (1852) | 870 (1918) | 900 (1984) | |
8 Volumes and weights include housing, pipework, standard accessories.
Standard Documentation9
- Certificate of Conformity to Quality Standards
- Final Inspection Certificate
- Installation/Operating Manual (IOM)
9 Additional documentation packages can be ordered.
Dimensional information of Filter System, SARP (with Riser Pipe)
Dimensional information of Filter System, SA (without Riser Pipe)
Type
Housings, Vessels, or Assemblies
Ordering Information
This is a guide to the part numbering structure and possible options only. For availability of specific options, please contact Pall.
Part Number: SPMS SA (RP) [1]
Example Part Number: SPMS SA 400 (without riser pipe)
Example Part Number: SPMS SA RP 400 (with riser pipe)
Lifting device enables insertion and removal of the entire stack of modules. Spacer pictured at the bottom enables lowering module stack onto a suitable raised surface.
Hooks on the lifting device grab the bottom of the SUPRApak module stack for easy handling.
Different bowl heights offer flexibility.
For applications requiring minimized mixing zones, a riser pipe which splits the feed fluid flow is available.
The torque unit is an external tensioning device, which provides reliable and secure operation without bypass. The filtrate vent, mounted on the torque unit, enables release of air from the filtrate inside the module core. The feed fluid vent assembly enables venting of air from the unfiltered fluid.
Part Number: SPMS SA (RP) [1]
Example Part Number: SPMS SA 400 (without riser pipe)
Example Part Number: SPMS SA RP 400 (with riser pipe)
Note: See bold reference code in the table.
Table 1
Code | Bowl Height and Configuration | Number of SUPRApak Modules |
400 | 4-High Bowl | 16 |
500 | 5-High Bowl | 20 |
600 | 6-High Bowl | 24 |
Optional Accessories
Part No. | Description | Details |
ACS1056AA | Sight Glass DN 100 | For filtrate side piping |
25590-022610 | Hot Fluid Core | 1.4404 (AISI 316L SS) |
25590-0226-0110 | Hot Fluid Core Extension Z1 | 1.4404 (AISI 316L SS) |
25590-0226-0210 | Hot Fluid Core Extension Z2 | 1.4404 (AISI 316L SS) |
ACS1036AA | Hook Spanner DN 10-20 | Tool |
ACS1037AA | Hook Spanner DN 25-100 | Tool |
20040118-34 | 3-4 High Lifting Device (incl. Stand) | Supplied with spacer |
20040118-56 | 5-6 High Lifting Device (incl. Stand) | Supplied with spacer |
ACS1067GS | Inlet /Outlet Adaptor (DN 100 – 4 inch clamp coupling) |
Adaptor for piping adaption from DN to ISO 2852 clamp coupling connection |
10For hot fluid filtration (>40 °C/ >104 °F) select Hot Fluid Core for the top module in the stack and add Hot Fluid Core Extension Z1 (1-high section) and/or Hot Fluid Core Extension Z2 (2-high section) as required.
Lifting device enables insertion and removal of the entire stack of modules. Spacer pictured at the bottom enables lowering module stack onto a suitable raised surface.
Hooks on the lifting device grab the bottom of the SUPRApak module stack for easy handling.
Different bowl heights offer flexibility.
For applications requiring minimized mixing zones, a riser pipe which splits the feed fluid flow is available.
Spare Parts
Part No. | Description | Details |
ACS1057EM | Housing O-Ring | EPDM |
ACS1070AA | Torque Unit | Torque unit with filtrate vent |
ACS1041AA | Torque Unit Rod Seal | EPDM |
ACS1043AA | Torque Unit Guide Bush | Torque unit spare part |
ACS1071JM | Torque Unit Clamp Nut | Torque unit spare part |
ACS0951AM | Pressure Gauge DN 25 | For feed fluid and filtrate sides |
ACS1056AA | Sight Glass DN 100 | For filtrate side piping |
ACS1068AA | Sight Glass DN 25 | For feed fluid vent |
ACS1060CA | Butterfly Valve DN 100, Manual | For feed fluid and filtrate side piping |
ACS1061CA | Butterfly Valve DN 25, Manual | For feed fluid and filtrate side drain |
ACS1058CA | Butterfly Valve DN 25, Pneumatic | For feed fluid vent |
ACS1059CA | Butterfly Valve DN 15, Pneumatic | For filtrate vent |
ACS1062CA | Non Return Valve DN 100 | For filtrate side piping |
ACS1063CA | Safety Relief Valve DN 50 | For feed fluid piping |
ACS1064EM | DN 100 Seal | EPDM |
ACS1065EM | DN 50 Seal | EPDM |
ACS1052EA | DN 25 Seal | EPDM |
ACS1069EM | DN 15 Seal | EPDM |
ACS1066CA | Pilot Valve | Drive for feed fluid and filtrate vent |
The torque unit is an external tensioning device, which provides reliable and secure operation without bypass. The filtrate vent, mounted on the torque unit, enables release of air from the filtrate inside the module core. The feed fluid vent assembly enables venting of air from the unfiltered fluid.
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.