MEMBRAcart XP Filter Cartridges product photo Primary L

MEMBRAcart XP Filter Cartridges

MEMBRAcart XP filter cartridges are hydrophilic membrane filters designed for removal of spoilage microorganisms in the food and beverage industry.

MEMBRAcart XP filter cartridges are filters constructed from an inert polyethersulfone membrane which, in combination with the robust construction enables excellent mechanical strength and exposure to repeated hot water, chemical and steam sanitization cycles for long service life.

The cartridges are available in single open ended (SOE) configurations to fit in sanitary housings to ensure effective microbial removal and assembly integrity.

 
Features Benefits
Inert polyethersulfone (PES) filter material • Maintaining organoleptic characteristics of the filtered product
• Wide range of chemical compatibility
Cartridges resistant to numerous sanitization cycles • Economical operation
• Consistent filtrate quality
Hydrophilic membrane • Easy to wet and integrity test
Validated with Food & Beverage microorganisms • Increased process safety
• Reliable reduction of microorganisms
Individually serialized cartridges • Full traceability
Integrity testable • Brand protection
• Documentation for quality records
Multiple adaptor options • Easy installation into sanitary housings
 

Quality

  • Cartridges produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

Food Contact Compliance

Please refer to the Pall website http://www.pall.com/foodandbev for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

Microbial Removal Rating

 
Grade Test Organism Titer Reduction Value1 (LRV)
B Serratia marcescens
(ATCC 14756)
≥ 10
K S. cerevisiae Yeast free
 
1Challenges were performed at a level of ≥107 per cm2 of effective filtration area on new and unused filters.


Contact Us
* Required

Order Products

Description

MEMBRAcart XP filter cartridges are hydrophilic membrane filters designed for removal of spoilage microorganisms in the food and beverage industry.

MEMBRAcart XP filter cartridges are filters constructed from an inert polyethersulfone membrane which, in combination with the robust construction enables excellent mechanical strength and exposure to repeated hot water, chemical and steam sanitization cycles for long service life.

The cartridges are available in single open ended (SOE) configurations to fit in sanitary housings to ensure effective microbial removal and assembly integrity.

 
Features Benefits
Inert polyethersulfone (PES) filter material • Maintaining organoleptic characteristics of the filtered product
• Wide range of chemical compatibility
Cartridges resistant to numerous sanitization cycles • Economical operation
• Consistent filtrate quality
Hydrophilic membrane • Easy to wet and integrity test
Validated with Food & Beverage microorganisms • Increased process safety
• Reliable reduction of microorganisms
Individually serialized cartridges • Full traceability
Integrity testable • Brand protection
• Documentation for quality records
Multiple adaptor options • Easy installation into sanitary housings
 

Quality

  • Cartridges produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

Food Contact Compliance

Please refer to the Pall website http://www.pall.com/foodandbev for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

Microbial Removal Rating

 
Grade Test Organism Titer Reduction Value1 (LRV)
B Serratia marcescens
(ATCC 14756)
≥ 10
K S. cerevisiae Yeast free
 
1Challenges were performed at a level of ≥107 per cm2 of effective filtration area on new and unused filters.

Specifications

Materials of Construction

 
Component Description
Filter medium Polyethersulfone (hydrophilic)
Support and drainage Polypropylene
Core, Cage, End Cap and Fin End Polypropylene
Adaptor Polypropylene with internal stainless steel reinforcing ring
O-ring seal Ethylene propylene rubber or Silicone elastomer
 

Technical Information

 
Nominal Length Nominal Filter Area
254 mm (10 in.) 0.6 m2 (6.5 ft2)
508 mm (20 in.) 1.2 m2 (13 ft2)
762 mm (30 in.) 1.8 m2 (19.5 ft2)
508 mm (20 in.) 2.4 m2 (26 ft2)
 

Operating Characteristics in Compatible Fluids2

The maximum allowable differential pressure in a forward flow direction for MEMBRAcart XP filters is shown in the table below.

 
Temperature Max. Allowable Differential Pressure
Up to 40 °C (104 °F) 500 kPa (5 bard) (72.51 psid)
40 °C to 80 °C (104 °F to 176 °F) 300 kPa (3 bard) (43.51 psid)
 
2 Compatible fluids are defined as those which do not swell, soften or attack any of the filter components.

Sterilization and Sanitization

 
Media Temperature Maximum Cumulative Time/Cycles3
Steam 125 °C (257 °F) 50 hours / 150, 20 minute cycles
Hot water 85 °C (185 °F) 50 hours / 100, 30 min cycles
Peracetic acid (PAA), 325 ppm PAA (1275 ppm H2O2 to give 1600 ppm of total peroxides) ambient 2000 hours
 
3 Measured under laboratory test conditions. The actual cumulative time depends on the process conditions. For applications requiring sterilization or sanitization Pall recommends the use of Code 7 adaptors to ensure filter sealing after cooling. Cartridges should be cooled to system operating temperature prior to use. Contact Pall for recommended procedures.

Pressure Drop vs Liquid Flow Rate4

4 Typical initial clean media differential pressure (dP) per 254 mm (10 in.) cartridge for water at 20 °C (68 °F); viscosity 1 centipoise. For 508, 762 mm and 1016 mm configurations divide the differential pressure by 2, 3, and 4 respectively.

Type

Filter Cartridges

Use

Filtration | Liquid

Ordering Information

Cartridge Part Number

AB [Table 1] M [Table 2] X [Table 3] W [Table 4]

This is a guide to the Part Numbering structure only. For specific options, please contact Pall.

Table 1: Nominal Length

 
Code Description
1 254 mm (10”)
2 508 mm (20”)
3 762 mm (30”)
4 1016 mm (40”)
 

Table 2: Microbial Removal Rating

 
Code Microbial Removal Rating
B 0.45 μm
K 0.65 μm
 

Table 3: Adaptor

 
Code Description
3 SOE – single open end with flat closed end and external 222 O-rings
7 SOE – single open end with fin end, 2 locking tabs and external 226 O-rings
8 SOE – single open end with fin end and external 222 O-rings
28 SOE – single open end with fin end, 3 locking tabs and external 222 O-rings
 

Table 4: O-Ring Seal Material

 
Code Description
H4 Silicone Elastomer
J Ethylene Propylene Rubber
 