Description
Features
- Flows to 600 L/min (158 US gpm)
- Pressures to 28 bar (400 psi)
- Port size 3"
- Unique Ultipleat (laid-over pleat) filter medium pack
- Coreless, cageless element configuration
- Pall Stress-Resistant Technology (SRT) Media
- In-to-out filter element flow path
- Duplex filter configuration allows uninterrupted flow to the system when changing filter elements
The UR329 Series is a Preferred Product Line utilizing Stress-Resistant Technology. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.
Specifications
Filter Housing
- Maximum Allowable Working Pressure:
28 bar (400 psi) - Rated Fatigue Pressure:
23 bar (334 psi) 106 cycles per NFPA T2.06.01R2-2001 - Typical Burst Pressure:
145 bar (2100 psi) - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids - Materials of Construction:
Manifold and check valve: Aluminum alloy Tube: Carbon steel
Head and cover: Ductile Iron
Filter Element
- Filter Element Burst Pressure:
10 bard (150 psid) - Athalon™ Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 2 fluids only. Consult Sales for other fluid gas group suitability.
Length Code | Overall Length mm (in.) | Element Removal Clearance mm (in.) | Empty Weight kg (lb) |
40 | 1372 (54.02) | 1040 (41) | 117 (259) |
* Other housing configurations available on application
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.Element Pressure Drop
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.310 Series Filter Elements — bard/1000 L/min (psid/US gpm)
Length Code | AZ | AP | AN | AS | AT |
40 | 1.10 (0.060) | 0.46 (0.025) | 0.36 (0.020) | 0.26 (0.014) | 0.16 (0.009) |
Sample ΔP calculation
UR329 Series 20" length housing with F48 (3" SAE) split flange ports using AN grade media. Operating conditions 200 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.2 x 1.2/0.9) bard (housing)
+ ((200 x 0.72/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.26 bard (housing) + 0.3 bard (element)
= 0.56 bard (8.1 psid)
Type
Housings, Vessels, or Assemblies
Ordering Information
Please select only from the following list of standard filter housing options.
The specification of each filter housing part number is outlined in the tables below.
Seal Kit P/N: UR 329 SK Z
For applications with operating conditions greater than 200 bar (3000 psi)
Other options available; contact Pall.
Available UR329 Series Options
UR329CD48 40ZA9YS60 UR329CF48 40ZA9YS60 UR329CD48 40ZG9YS60 UR329CF48 40ZG9YS60 | |
The specification of each filter housing part number is outlined in the tables below.
Section 1
Housing P/N: UR 329 C [Table 1] ++ [Table 2] Z [Table 3] 9 YS60Seal Kit P/N: UR 329 SK Z
Note: Pall Athalon™ filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The number ‘9’ at the end of the Housing P/N designates 2 indicator ports per filter tower, one fitted with a plastic shipping plug and the other with a blanking plug.
*Other seal material options are available; Contact Pall.
Table 1: Inlet/Outlet Port Options
Code | Port |
D48 | 3" Flange J518C code 61 with 5/8"-11 UNC holding bolts |
F48 | 3" ISO 6162 split flange with M16 x 2.00 holding bolts |
Table 2: Housing Length Options
Code | Length (in)* |
40 | 40 |
* Nominal length
Table 3: Housing Bypass Valve Options
Code | Valve |
A | 1.7 bard - 25 psid |
G | 4.5 bard - 65 psid |
Section 2
Element P/N: UE 310 [Table 1] [Table 2] ZNote: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 1: Filter Element Options
Code | ßx(c) ≥1000 based on ISO 16889 | CST Rating* |
AZ | 3 | 07/04/01 |
AP | 5 | 11/08/03 |
AN | 7 | 13/09/04 |
AS | 12 | 15/11/06 |
AT | 22 | 16/14/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Table 2: Filter Element Length Options
Code | Length (in)* |
40 | 40 |
* Nominal length
Section 3 (At least one Differential Pressure Indicator or ‘B’ type blanking plug must be ordered)
Differential Pressure Indicator P/N: RC [Table 1] Z 091 Z [Table 2]
Note: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 1: Indicator Options
For applications with operating conditions less than 200 bar (3000 psi)Code | Brass Option indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
For applications with operating conditions greater than 200 bar (3000 psi)
Code | Stainless Steel indicator |
778NZ | Visual filter with thermal lockout |
861CZ | Electrical Switch (SPDT) with 6” leads |
861CZ* | Electrical switch (SPDT) with Hirschmann connector |
771BZ | Electrical switch (SPDT) with 3-pin |
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 7B.
Table 2: Differential Pressure Indicator Material
Code | Pressure Setting |
Omit | Brass Indicator: use at operating pressures < 200 bar (3000 psi) |
SS | Stainless Steel Indicator: recommended for high pressure cycle applications with pressures > 200 bar (3000 psi) |
Other setting options are available; contact Pall.
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.