Pall-Fit™ Elements for Parker Filter Housings product photo Primary L

Pall-Fit™ Elements for Parker Filter Housings

Upgrade Parker Filter Elements to Pall Ultipor® III or Dirt-Fuse® Filter Media

Pall-Fit elements allow you to use Pall Ultipor filters in your existing filter housings. Ultipor filters optimize efficiency and service life, while maintaining low differential pressure and high strength. This allows you to economically achieve superior system cleanliness for maximum protection.

 



Contact Us
* Required

Description

Upgrade Parker Filter Elements to Pall Ultipor® III or Dirt-Fuse® Filter Media

Pall-Fit elements allow you to use Pall Ultipor filters in your existing filter housings. Ultipor filters optimize efficiency and service life, while maintaining low differential pressure and high strength. This allows you to economically achieve superior system cleanliness for maximum protection.

 

Specifications

Filter Medium:
Inert inorganic fibers, impregnated and bonded with epoxy resin.

Filter Construction:
Ultipor III – Upstream and downstream nylon support mesh. Each pleat firmly bonded to helical wrap for superior stability.
Dirt-Fuse – Upstream and downstream wire support mesh.

Filter Element Hardware:
Corrosion protected steel end caps and core. Grommet seals on 2252 series.

Fluid Compatibility:
(per ISO 2943)
Compatible with petroleum oils, water-glycols, water-oil emulsions, and HWCF.
Use fluorocarbon seals for industrial phosphate esters, diesters, and specified synthetics.

Temperature range:
Nitrile seals -45°F to 225°F 
Fluorocarbon seals -20°F to 250°F 
140°F max. in water based fluids.

Collapse Pressure Rating:
(per ISO 2941)
150 psid – 2252 Series
290 psid – 9020, 9700 Series
3000 psid – 9021, 9701 Series

Multipass Filtration Ratings:
(per ISO 16889)

 

Performance

Technical Information

Pall
Media Grade
µm Rating for ß Value
ß=200
µm(c) Rating for ß Value
ß=2 ß=10 ß=75 ß=100 ß=200 ß=1,000
Ultipor III
KP 3 <2 <2 3.1 3.3 3.8 5
KN 6 2.1 3.4 5.0 5.2 5.7 7
KS 12 3.2 5.5 8.3 8.7 9.7 12
KT 25 7.2 11 15.8 16.5 18.2 22
Dirt-Fuse
DP 3 <2 <2 3.0 3.2 3.8 5
DT 17 3.3 6.3 10.1 10.7 12 15

Type

Filter Cartridges

Ordering Information

Parker Housing Model No. Reference Pall Element Part No. Dimensions (ref.) DP Factors
(psid/gpm -150 SUS)
  OD Length ID KP KN KS KT
RF2-1, IL2-1, DIL2-1 HC2252F**10H 3.6 9.30 1.72 N/A 0.13 N/A N/A
RF2-2, IL2-2, DIL2-2 HC2252F**19H 3.6 18.60 1.72 N/A 0.06 N/A N/A
15P-1 HC9020F**4H 1.8 4.47 1.00 0.82 0.54 0.35 0.21
15P-2 HC9020F**8H 1.8 8.20 1.00 0.41 0.27 0.18 0.11
50P-1 HC9700F**9H 3.9 9.25 1.60 0.11 0.08 0.06 0.04
50P-2 HC9700F**18H 3.9 18.50 1.60 0.05 4.00 0.03 0.02
Above elements, media grades (**) KP, KN, KS, and KT, are all used in housings with bypass valves.



Parker Housing Model No. Reference Pall Element Part No. Dimensions (ref.) DP Factors
(psid/gpm -150 SUS)
    OD Length ID DP DT
15P-1 HC9021F**4H 1.8 4.47 1.00 2.71 0.68
15P-2 HC9021F**8H 1.8 8.20 1.00 1.35 0.34
50P-1 HC9701F**9H 3.9 9.25 1.60 0.38 0.10
*Dirt-Fuse elements, media grades (**) DP and DT, are used in non-bypass housings.