Description
Features
- Flows to 125 L/min (35 US gpm)
- Pressures to 17 bard (250 psid)
- Port size 1"
- Spin on cannister
- Ultipor® III filter medium pack
- Out-to-in filter element flow path
The 7400 Series is a Preferred Product Line utilizing Ultipor® III filter medium. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
Specifications
Notes and Specifications Filter Housing
- Fatigue Pressure Rating
17 bar (250 psi) (60,000 cycles 0-250 psi) - Typical Burst Pressure:
28 bar (400 psi) - Filter Element Collapse Pressure:
7 bard (100 psid) - Fluid Compatibility:
Compatible with all petroleum oils and most water glycols, water-oil
emulsions, and synthetic hydraulic and lubricating fluids - Temperature Range:
-29 ˚C to 120 ˚C (-20 ˚F to 225 ˚F)
60 ˚C (140 ˚F) maximum in HWCF or water glycols - Bypass Valve Setting:
1.7 bard (25 psid)
3.4 bard (50 psid)
Non-bypass - Indicator Pressure Setting:
1.1 bard (16 psid) with ‘A’ valve option
2.4 bard (35 psid) with ‘B’ and ‘W’ valve option - Housing Materials of Construction:
Cast iron head
Dimensional Drawings
Dimensions in mm (inches)
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.Element Pressure Drop
Multiply actual flow rate times factor in
7400 Series Element DP Factors (psid/gpm )
Length Code | CZ | CP | CN | CS | CT |
4” | 0.82 | 0.36 | 0.30 | 0.22 | 0.15 |
8” | 0.43 | 0.19 | 0.15 | 0.12 | 0.08 |
Type
Ordering Information
Section 1 Housing P/N:
Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Housing part number designates indicator port is fitted with a plastic shipping plug.
Part Number | |
HH7400A12B1 | |
HH7400A16A1 | |
HH7400A16B1 | |
HH7400A16W1 | |
HH7400C12B1 | |
HH7400C16A1 | |
HH7400C16B1 | |
HH7400C16W1 | |
Part Number Breakdown | |
HH = housing with fluorocarbon seals | |
7400 = 7400 series spin-on housing | |
A12 = ¾” SAE J514 straight thread port | |
A16 = 1” SAE J514 straight thread port | |
C12 = ¾” BSP ISO 228 threads | |
C16 = 1” BSP ISO 228 threads | |
A = 1.7 bard (25 psid) bypass valve | |
B = 3.4 bard (50 psid) bypass valve | |
W = Non-bypass | |
1 = 1 indicator warning device port | |
Section 2 Spin-On Can P/N: HC7400 S[Table 1] [Table 2] H
Table 1: Filter Performance Ratings
Code | ßx(c) ≥1000 per ISO 16889 | ISO Code Rating per Stress- Resistance Test (80% Δp)* |
CZ | 3 | 10/08/03 |
CP | 5 | 12/09/07 |
CN | 7 | 14/11/06 |
CS | 12 | 15/11/06 |
CT | 22 | 16/14/08 |
* based on 60 psid terminal pressure drop
Table 2: Length Options
Code | Description |
4 | 4” nominal length |
8 | 8” nominal length |
Section 3
Differential Pressure Indicator P/N: RC [Table 1] Z [Table 2] Z
Note: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 4: Indicator Options
Code | Brass Option indicator |
A218M | |
A218R | with Red and Green LED indicators |
A219D | Visual indicator |
Table 2: Differential Pressure Setting Options
Code | Description |
084 | For A valve option (1.1 bar – 16 psid) |
090 | For B and W valve options (2.4 bard - 35 psid) |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.