HNP074 Series product photo Primary L

HNP074 Series

FLUID CONDITIONING PURIFIER

70 L/min • Fluid viscosities to 700cSt


Reliability of systems, the service life of system components and fluids are extended by minimising water contamination.

The Pall HNP074 Purifier is designed to remove water from fluids thereby maintaining lubricity properties, minimising fluid oxidation and reducing aeration.
  • High performance water and gas removal
  • Simple operation
  • Remote monitoring option
  • Extension of system fluid life
  • Increased equipment reliability
  • Minimized corrosion within systems
  • Reduced fluid disposal
  • Reduced operating costs

    Pall purifiers remove 100% of free water and in excess 80% of dissolved water. They also remove 100% of free and entrained gases and in excess of 80% of dissolved gases.

    The Pall HNP074 fluid conditioning purifier can be used as a fixed installation or portable unit that is easily removed and connected to any fluid system.

    This purifier design is based on the existing range of Pall fluid conditioning products, it allows for easy operation and control.

    Automated controls, integral to the unit constantly monitor the operation of the purifier and will safely shutdown the unit if acceptable limits are exceeded.


Contact Us
* Required

Description

FLUID CONDITIONING PURIFIER

70 L/min • Fluid viscosities to 700cSt


Reliability of systems, the service life of system components and fluids are extended by minimising water contamination.

The Pall HNP074 Purifier is designed to remove water from fluids thereby maintaining lubricity properties, minimising fluid oxidation and reducing aeration.
  • High performance water and gas removal
  • Simple operation
  • Remote monitoring option
  • Extension of system fluid life
  • Increased equipment reliability
  • Minimized corrosion within systems
  • Reduced fluid disposal
  • Reduced operating costs

    Pall purifiers remove 100% of free water and in excess 80% of dissolved water. They also remove 100% of free and entrained gases and in excess of 80% of dissolved gases.

    The Pall HNP074 fluid conditioning purifier can be used as a fixed installation or portable unit that is easily removed and connected to any fluid system.

    This purifier design is based on the existing range of Pall fluid conditioning products, it allows for easy operation and control.

    Automated controls, integral to the unit constantly monitor the operation of the purifier and will safely shutdown the unit if acceptable limits are exceeded.

Specifications

 Dimensions:  725 mm x 1585 mm x 1865 mm
(28.5 ” x 62.4 ” x 73.5 ”)
 Dry mass:  385 kg (849 lb) approx
 Inlet connections:  2 ” BSPP or 2 ” NPT
 Outlet connections: 1½ ” BSPP or 1½ ” NPT
 Inlet pressure: -0.4 bar g (-40kPag / -5.8 psi g) minimum
1.5 bar g (150kPag / 44 psi g) maximum
System back pressure: 3.5 bar g (350 kPag / 50.8 psi g) maximum
 Fluid operating temperature:  +10 ºC (50 °F) to +70 ºC (158 °F)
 Fluid viscosity: 700 cSt (3300 SUS) maximum
 Operating vacuum:   -0.6 barg to -0.9 bar g (adjustable)
(-60 kPag / -8.7 psi g to
-90 kPag / -13.1 psi g)
 Power supply: See Table 1
 Total Motor power:  5.5 kW @ 50 Hz, 3Ø
7.3 kW @ 60 Hz, 3Ø
 Materials of Construction  
 Base frame:  Epoxy painted carbon steel
 Vacuum vessel:  304 Stainless Steel
 Fittings and fasteners:  Corrosion protected carbon steel
 Control box:  Epoxy painted carbon steel
Hydraulic hoses and seals:  Fluorocarbon

Note: Pall HNP076 series fluid conditioning purifiers comply with all applicable EC directives and bear the CE mark.

Type

Oil Purifiers

Use

Filtration, Polishing, Prefiltration, Removal

Ordering Information

Purifier
P/N: HNP023 [Table 1/Code 1] [Table 1/Code 2]   Z   [Table 2] [Table 3] [Table 4] [Table 5]

Note: Z indicates fluorocarbon seals and AQP Elastomer Tube* hoses are standard. Other options are available; contact Pall.

Please select only from the following list of standard purifier options:

 
HNP076S3ZCPENA
HNP076S3ZCPENB
HNP076S3ZCPENC
HNP076S3ZCPEND
HNP076S3ZCPDEA
HNP076S3ZCPDEB
HNP076S3ZCPDEC
HNP076S3ZCPDED
HNP076S3ZCPFRA
HNP076S3ZCPITA
HNP076S3ZCPITC
HNP076R3ZCTENA
HNP076R3ZCPENB
HNP076R3ZCPRUB
HNP076S3ZCPPLB

Table 1 - Standard Voltage

 
Code Voltage
R 380 VAC
S 400 VAC
 

Standard voltages only listed. Other voltages will be available on request - price and lead time will be provided on application.

Table 2 - Frequency Options

 
Code Frequency
3 50 Hz, 3 phase
 

Table 3 - Seal Type

 
Code Material
Z Fluorocarbon
 

Table 4 - Mounting Options

 
Code Mounting Type
C Mobile (2 fixed and
2 swivel castors)
 

Table 5 - Process Port Connection Options

 
Code 2” inlet / 1½”
Outlet Connections
P BSP ISO 228 threads
 

Table 6 - Language Options

 
Code Language
DE German
EN English
RU Russian
PL Polish
FR French
IT Italian
 

Table 7 - Optional Factory Fitted Kits

 
Code Kit
A No optional kit(s) fitted
B 5m electrical cable, socket and plug, in accordance with IEC 60309 to electrically connect the purifier
C Gauge points, inlet and outlet pressure gauges and an inlet sight flow indicator to allow fluid condition and pressures to be monitored
D Both kits B and C
 

Optional inlet and outlet hose 5m P/N: HNP076HZ

Replacement Filter Element P/N: UE610 [Table 1] 40Z

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 1 - Element Rating

 
Code Bx(c) >2000 based on ISO16889
AZ 3
AP 5
AN 7
AS 12
AT 22
 

Replacement Air Breather
P/N: HC0293SEE5

Reviews

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.