Description
Features
- Flows to 225 L/min (60 US gpm)
- Pressures to 420 bard (6100 psid)
- Port size 1 ¼ "
- Patented Ultipleat® (laid over pleat) filter medium pack
- Coreless, cageless, element configuration
- Pall Stress Resistant Technology media
- In-to-out filter element flow path
The UR229 Series is a Preferred Product Line utilizing Stress-Resistant Technology. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
Specifications
Filter Housing
- Maximum Allowable Working Pressure:
110 bar (1,600 psi) - Rated Fatigue Pressure:
110 bar (1,600 psi)
106 cycles per NFPA T2.06.01R2-2001 - Fluid Compatibility:
Compatible with petroleum oils, water glycols, water-oil emulsions, and most synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals:
-29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF orwater glycol fluids - Materials of Construction:
Head and cover: Ductile iron
Tube: Carbon steel
Transfer and check valve: Steel with zinc plating
Filter Element
- Filter Element Burst Pressure:
10 bard (145psid ) - Athalon Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design.
Dimensional Drawings
Dimensions in mm (inches)
*NOTE: The inlet/outlet flange connection ports have been configured with a dual 90º axis option to allow flexibility of mounting and piping arrangements. This offers various piping orientations and mounting flexibility when using SAE flange elbow connections.
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 1 and 2 fluids only. Consult Sales for other fluid gas group suitability.
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity
Element Pressure Drop
Multiply actual flow rate times factor in
210 Series Filter Elements – bard/1000 L/min (psid /US gpm )
Length Code | AZ | AP | AN | AS | AT |
13 | 5.95 (0.327) | 2.52 (0.139) | 1.70 (0.093) | 1.05 (0.058) | 0.80 (0.044) |
20 | 3.95 (0.217) | 1.68 (0.092) | 1.13 (0.062) | 0.70 (0.038) | 0.53 (0.029) |
Sample ΔP calculation
UR229 Series 13” length housing with F20 (1¼” SAE) split flange ports using AN grade media. Operating conditions 75 L/min (20 USgpm) flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP
= ΔP housing + ΔP element
= (0.5 x 1.2/0.9) bard (housing)
+ ((75 x 1.7/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.67 bard (housing) + 0.27 bard (element)
= 0.94 bard (13.63 psid)
Type
Ordering Information
For new installations, select one complete part number from each section below
Section 1 Housing P/N:
Note: Pall filter housings are supplied without filter elements or filter change out warning devices. Never operate the filter housing unless a filter element is fitted and all warning device ports are sealed.
Housing part number designates indicator port is fitted with a plastic shipping plug.
Part Number | Description |
UR229CD2013ZS00001 | UR229CD2013ZG1NYR85 |
UR229CD2013ZS00003 | UR229CD2013ZA1NYR85 |
UR229CD2020ZS00001 | UR229CD2020ZG1NYR85 |
UR229CD2020ZS00005 | UR229CD2020ZA1NYR85 |
UR229CF2013ZS00001 | UR229CF2013ZG1NYR85 |
UR229CF2013ZS00003 | UR229CF2013ZA1NYR85 |
UR229CF2020ZS00001 | UR229CF2020ZG1NYR85 |
UR229CF2020ZS00004 | UR229CF2020ZA1NYR85 |
Part Number (Description) Breakdown |
UR229C = UR229 series housing, cover service |
C20 = 1¼” BSP ISO228 thread ports |
D20 = 1¼” Flange ports SAE J518C code 61 (207 bar/3000) |
F20 = 1¼” ISO 6162 split flange ports (250 bar/3625 psi max pressure) |
13 = 13 inch nominal length |
20 = 20 inch nominal length |
Z = Fluorocarbon seals |
G = 4.5 bard (65 psid) bypass valve |
A = 1.7 bard (25 psid) bypass valve |
1 = 1 indicator warning device port |
N = No secondary port |
YR85 = Iron/Steel construction |
Section 2
Element P/N: UE 210 [Table 1][Table 2] Z
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 1: Filter Element Options |
||
Code | ßx(c) ≥1000based on ISO 16889 | CST Rating* |
AZ | 3 | 07/04/01 |
AP | 5 | 11/08/03 |
AN | 7 | 13/09/04 |
AS | 12 | 15/11/06 |
AT | 22 | 16/14/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205 |
||
Table 2: Filter Element Length Options |
||
Code | ||
13 | 13inch nominal length | |
20 | 20inch nominal length | |
* Nominal length |
Section 3 Differential Pressure Indicator P/N: RC [Table 3] Z [Table 4] Z [Table 5]
(One Differential Pressure Indicator or ‘B’ type blanking plug must be ordered for each filter tower)
Note: If no Differential Indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered seperately and fitted to replace the shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 3: Indicator Options
Code | Brass Option indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
Code | Stainless Steel Option Indicator |
778N | Visual filter with |
861C | Electrical Switch (SPDT) with 6" leads |
771B | Electrical switch (SPDT) with 3-pin |
Table 4: Indicator Pressure Setting Option
Code | Description |
084 | For A valve option housings (1.1. bard. 16 |
091 | For G valve option housings (3.5. bard. 50 |
Table 5: Differential Pressure Indicator Material
Code | Pressure Setting |
Omit | If Brass Indicator is selected in Table 3 |
SS | If Stainless Steel Indicator is selected in Table 3 (recommended for |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.