Description
Features
- Flows to 250 L/min (66 US gpm)
- Pressures to 420 bar (6090 psi)
- Port size 1 in. and 11⁄4 in.
- Out-to-in filter element flow path
Specifications
Filter Housing
- Maximum Allowable Working Pressure:
420 bar (6090 psi) - Rated Fatigue Pressure:
0-240 bar (0-3480 psi) per NFPA T2.6.1 R2-2001
CAT C/90. Verified by testing at 0-280 bar (0-4060 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids - Temperature Range:
Maximum operating temperature: 120 ˚C (250 ˚F)
Minimum operating temperature: -25 ˚C (-13 ˚F)
Minimum ambient temperature: -40 ˚C (-40 ˚F) - Bypass Valve Settings:
‘G’ option 4.5 ± 0.5 bard (65 ± 7 psid) - Indicator Pressure Settings:
3.4 ± 0.4 bard (50 ± 6 psid) - Materials of Construction:
Head: SG Iron
Bowl: Carbon steel
Filter Element
- Filter Element Burst Pressure:
10 bard (145 psid) - Filter Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Polyamide endcaps. Corrosion protected carbon steel core.
Dimensional Drawings
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.HCG300 Filter Elements – bard/1000 L/min (psid/US gpm)
Length Code | CN | CS | KD | CT |
4 | 5.60 (0.34) | 4.17 (0.23) | 2.68 (0.15) | 2.87 (0.16) |
8 | 3.04 (0.17) | 2.26 (0.12) | 1.41 (0.08) | 1.56 (0.09) |
10 | 2.42 (0.13) | 1.80 (0.10) | 1.13 (0.06) | 1.24 (0.07) |
Multiply actual flow rate times factor in table above to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.
Sample ΔP calculation
G410 Series 8 in. length housing with C20 ports using KN grade media. Operating conditions 100 L/min flow rate using a hydraulic fluid at 45 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.22 x 1.2/0.9) bard (housing)
+ ((100 X 2.75/1000) X 45/32 X 1.2/0.9) bard (element)
= 0.29 bard (housing) + 0.51 bard (element)
= 0.81 bard (11.8 psid)
Type
Housings, Vessels, or Assemblies
Ordering Information
Assembly P/N*:
Element P/N: HCG300F [Table 3] [Table 4] Z
Seal P/N: G400SKZ
- HZG410A16CSSG1X160
- HZG410A20CSKG1X160
- HZG410C16CNRG1X160
- HZG410C16CNSGBX160
- HZG410C16CSRG1X160
- HZG410C20CNSGBX160
- HZG410C20CSKGDX160
* Other options available, contact factory
Element P/N: HCG300F [Table 3] [Table 4] Z
Seal P/N: G400SKZ
Table 1: Housing Port Style Options
Code | Port Size | Port Style |
A16 | 1 in. | SAE J1926 straight thread |
A20 | 1 1⁄4 in. | |
C16 | 1 in. | BSP threads to ISO228 |
C20 | 1 1⁄4 in. | |
Table 2: Filter Element Options
Code | ßx(c) ≥1000 based on ISO 16889 |
CN | 7 |
CS | 12 |
KD | 19 |
CT | 22 |
Table 3: Length Options
Code | Element Length Code | Length (in)* |
R | 4 | 130.4 / 131.0 mm (5.13 / 5.16 in) |
S | 8 | 222.6 / 223.2 mm (8.76 / 8.79 in) |
K | 10 | 274.3 / 274.9 mm (10.8 / 10.82 in) |
* Normal Length
Table 4: Differential Pressure Indicator Options
Code | Indicator |
B | Machined port with blanking plug |
1 | Machined port with plastic shipping plug Indicator must be installed prior to operation |
D | Visual Indicator |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.