- Patented Ultipleat (laid-over pleat) filter medium pack
- Coreless, cageless element configuration
- Pall Stress-Resistant Technology (SRT) Media
- In-to-out filter element flow path
- Flows to 600 L/min (160 US gpm)
- Pressures to 420 bar (6100 psi)
- Ports, 11⁄2 in. top and side manifold mount
The UH319MM series filter assemblies are no longer available and are being replaced with Ultipleat® UH319 Filter Assemblies
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.
Filter Housing
- Maximum Working Pressure: 420 bar (6100 psi)
- Rated Fatigue Pressure: 0-240 bar (3500 psi) per NFPA T2.06.01R2-2001 CAT C/90 (1 million cycles), verified by testing at 0-280 bar (4050 psi) for 1 million cycles. Contact Pall for applications with higher pressures at lower cycles
- Typical Burst Pressure: 1500 bar (21,750 psi)
- Fluid Compatibility: Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
- Temperature Range: Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids
- Bypass Valve Setting: 4.5 bard (65 psid)
- Indicator Pressure Setting: 3.5 bard (50 psid)
- Materials of Construction: Head: Ductile Cast Iron Tube and Cover: Carbon steel
Filter Element
- Filter Element Burst Pressure: 10 bard (150 psid)
- Ultipleat SRT Element Construction: Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 2 fluids only. Consult Sales for other fluid gas group suitability.
'C' & 'H' Housings - S24 Side manifold mounting
Length Code | 'C' Option Overall Length mm (in.) | 'H' Option Overall Length mm (in.) | 'C' Option Element Removal Clearance mm (in.) | 'H' Option Element Removal Clearance mm (in.) | Empty Weight kg (lb) |
08 | 473 (18.62) | 521 (20.51) | 286 (11.26) | 140 (5.51) | 39.3 (86.7) |
13 | 608 (23.94) | 655 (25.79) | 421 (16.58) | 140 (5.51) | 44.3 (97.7) |
20 | 778 (30.63) | 826 (32.52) | 591 (23.27) | 140 (5.51) | 50.6 (111.6) |
40 | 1287 (50.67) | 1334 (52.52) | 1099 (43.27 ) | 140 (5.51) | 69.4 (153) |
'C' & 'H' Housings - K24 Top manifold mounting
Length Code | 'C' Option Overall Length mm (in.) | 'H' Option Overall Length mm (in.) | 'C' Option Element Removal Clearance mm (in.) | 'H' Option Element Removal Clearance mm (in.) | Empty Weight kg (lb) |
08 | 456 (17.95) | 470 (18.50) | 286 (11.26) | 140 (5.51) | 46.9 (103.4) |
13 | 591 (23.27) | 604 (23.78) | 421 (16.58) | 140 (5.51) | 51.9 (114.4) |
20 | 761 (29.96) | 775 (30.51) | 591 (23.27) | 140 (5.51) | 58.2 (128.3) |
40 | 1269 (49.96) | 1283 (50.51) | 1099 (43.27 ) | 140 (5.51) | 77 (169.8) |
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.
Element Pressure Drop
Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.
319 Series Filter Elements — bard/1000 L/min (psid/US gpm)
Length Code | AZ | AP | AN | AS | AT |
08 | 5.52 (0.302) | 2.30 (0.126) | 1.82 (0.100) | 1.32 (0.072) | 0.82 (0.045) |
13 | 3.31 (0.182) | 1.38 (0.076) | 1.09 (0.060) | 0.79 (0.043) | 0.49 (0.027) |
20 | 2.18 (0.120) | 0.91 (0.050) | 0.72 (0.040) | 0.52 (0.029) | 0.33 (0.018) |
40 | 1.10 (0.060) | 0.46 (0.025) | 0.36 (0.020) | 0.26 (0.014) | 0.16 (0.009) |
Sample ΔP calculation
UH319 Series 13 in. length housing with S24 (11⁄2 in.) side manifold mount ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP
= ΔP housing + ΔP element
= (0.30 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.40 (housing) + 0.68 bard (element)
= 1.08 bard (15.7 psid)
For new installations, select one complete part number from each section below
Section 1
Housing P/N:
UH 319 [Table 1] [Table 2] ++ [Table 3] Z G 9 X106
Note: Pall Ultipleat SRT filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The number '9' at the end of the Housing P/N designates 2 indicator ports, one fitted with a plastic shipping plug and the other with a bleed plug.
Seal Kit P/N:
UH 319 SKZ
*Other seal material options are available; Contact Pall.
Table 1: Housing Orientation Options
Code | Port |
C | Cap service (tube up) -standard |
H | Head service (tube down) |
Table 2: Housing Port Options
Code | Port |
K24 | 11⁄2 in. top mount manifold |
S24 | 11⁄2 in. side mount manifold |
Table 3: Housing Length Options
Code | Length (in.)* |
08 | 8 |
13 | 13 |
20 | 20 |
40 | 40 |
* Nominal length
Section 2
Element P/N:
UE 319 [Table 1] [Table 2] Z
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 1: Filter Element Options
Code | ßx(c) ≥1000 based on ISO 16889 | CST Rating* |
AZ | 3 | 08/04/01 |
AP | 5 | 12/07/02 |
AN | 7 | 15/11/04 |
AS | 12 | 16/13/04 |
AT | 22 | 17/15/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Table 2: Filter Element Length Options
Code | Length (in.)* |
08 | 8 |
13 | 13 |
20 | 20 |
40 | 40 |
* Nominal length
Section 3
(At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)
Differential Pressure Indicator P/N:
RC [Table 1] 091 Z [Table 2] [Table 3] [Table 4]
Note: Two Differential Pressure Indicators can be fitted on this housing
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 1: Differential Pressure Indicator Options*
Code | Indicator | 'H' Dim. |
778NZ | 'P' type Visual indicator with thermal lockout | 21mm (0.83 in.) |
860MZ | 'D' type Visual indicator with no thermal lockout | 21mm (0.83 in.) |
861CZ | 'L' type Electrical switch (SPDT) with 6 in.leads | 38mm (1.50 in.) |
861CZ | 'M' type Electrical switch (SPDT) with DIN43650 connector and matching cap | 78mm (3.07 in.) |
861CZ | 'R' type Electrical switch (SPDT) and neon light indicator with DIN43650 connector and cap | 89mm (3.50 in.) |
771BZ | 'S' type Electrical switch (SPDT) with 3-pin MS connector | 57mm (2.24 in.) |
* Other options available on application.
Table 2: Differential Pressure Indicator Material
Code | Pressure Setting |
Omit | Aluminium Alloy Indicator: use at operating pressures < 200 bar (3000 psi) |
SS | Stainless Steel Indicator: use at operating pressures > 200 bar (3000 psi) |
* Other setting options are available; contact Pall.
Table 3: 'M' & 'R'-Type Indicator Codes*
Code | Option |
YM | 'M' option |
YR | 'R' option |
* Use only if 'R' or 'M' Indicator is selected from Table 1
Table 4: 'R' Indicator Options
Code | Option |
110AC | 110V AC |
220AC | 220V AC |
24DC | 24V DC |
* Use only if 'R'Indicator is selected from Table 1