Description
Features
- Flows to 130 L/min (35 US gpm)
- Pressures to 450 bard (6500 psid)
- Port size: 1"
- Coralon™ filter medium pack
- Out-to-in filter element flow path
The 4510YE47/4511YE47 Series is a Preferred Product Line for high fatigue applications utilizing Coralon™ filter medium. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
Specifications
Filter Housing
- Fatigue Pressure Rating:
400 bar (5800 psi) per NFPA T2.6.1 R2-2001 Cat C/90 - Typical Burst Pressure:
1,600 bar (23,000 psi) - Filter Element Collapse Pressure:
20 bard (290 psid) – 9800 series
207 bard (3000 psid) – 9801 series - Fluid Compatibility:
Compatible with all petroleum oils and most water glycols,
water-oil emulsions, and synthetic hydraulic and lubricating fluids - Temperature Range:
-29 ˚C to 120 ˚C (-20 ˚F to 250 ˚F)
60 ˚C (140 ˚F) maximum in HWCF or water glycol with Supralon media - Bypass Valve Setting:
3.4 bard (50 psid) – 4510 series
Non-bypass – 4511 series - Indicator Pressure Setting:
2.4 bard (35 psid) – 4510 series
7 bard (100 psid) – 4511 series - Housing Materials of Construction:
Ductile iron head; steel bowl
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to S.G.
Element Pressure Drop
Multiply actual flow rate times factor in
9800 Series Element DP Factors (psid/US gpm )
Length | CZ | CP | CN | CS | CT |
4" | 1.83 | 0.72 | 0.56 | 0.40 | 0.26 |
8” | 0.95 | 0.37 | 0.29 | 0.21 | 0.13 |
9801 Series Element DP Factors (psid/gpm)
Length | CP | CT |
4” | 1.82 | 0.84 |
8” | 0.90 | 0.39 |
Type
Ordering Information
Housing Ordering Information
Section 1 Housing P/N:
Note: Pall filter housings are supplied without filter elements or filter change out warning devices. Never operate the filter housing unless a filter element is fitted and all warning device ports are sealed.
Housing part number designates indicator port is fitted with a plastic shipping plug.
Part Number | |
HZ4510A16RB9YE47 | HZ4511A16RW9YE47 |
HZ4510A16SB9YE47 | HZ4511A16SW9YE47 |
HZ4510C16RB9YE47 | HZ4511C16RW9YE47 |
HZ4510C16SB9YE47 | HZ4511C16SW9YE47 |
HZ4510E16RB9YE47 | HZ4511E16RW9YE47 |
HZ4510E16SB9YE47 | HZ4511E16SW9YE47 |
HZ4510G16RB9YE47 | HZ4511G16RW9YE47 |
HZ4510G16SB9YE47 | HZ4511G16SW9YE47 |
Part Number (Description) Breakdown |
HZ = housing with fluorocarbon seals |
4510 = 4510 series housing |
4511 = 4511 series housing (high collapse element) |
A16 = 1” SAE J514 straight thread port |
C16 = 1” BSP ISO 228 threads |
E16 = 1” Flange ports SAE J518C code 62 (414 bar/6000 psi max pressure) |
G16 = 1” ISO 6162 split flange ports (400 bar/5800 psi max pressure) |
R = 4” nominal length |
S = 8” nominal length |
B = 3.4 bard (50 psid) |
W = Non-bypass |
9 = 1 indicator warning device port |
YE47 = designed for high fatigue applications |
Section 2 Element P/N: HC980[Table 1] F[Table 2] [Table 3] Z
Table 1: Element OptionsCode | Description |
0 | 20 bard (290 psid) – for 4510 series |
1 | 207 bard (3000 psid) – for 4511 series |
Table 2: 9800 Series Filter Performance Ratings
Code | ßx(c) ≥1000 per ISO 16889 |
ISO Code Rating per Stress-Resistance Test (80% Δp)* |
CZ | 3 | 10/08/03 |
CP | 5 | 12/09/07 |
CN | 7 | 14/11/06 |
CS | 12 | 15/11/06 |
CT | 22 | 16/14/08 |
*based on 60 psid terminal pressure drop
Table 2: 9601 Series
Filter Performance Ratings
Code | ßx(c) ≥1000 based on ISO 16889 |
CP | 5 |
CT | 15 |
Table 3:
Length Options
Code | Description |
4 | 4” nominal length |
8 | 8” nominal length |
Section 3 Differential Pressure Indicator
P/N: RC [Table 1] Z [Table 2] Z [Table 3]
Note: If no Differential Pressure Indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the shipping plug.
Table 1
Code | Brass Option Indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
Code | Stainless Steel Option Indicator |
778N | Visual filter with thermal lockout |
861C* | Electrical switch (SPDT) with Hirschmann connector |
771B | Electrical switch (SPDT) with 3-pin |
Table 2: Differential Pressure Setting Options
Code | Description |
090 | For B valve option (2.4 bard - 35 psid) |
097 | For W valve option (7 bard – 100 psid) |
Table 3: Differential Pressure Indicator Material
Code | Description |
Omit | If Brass Indicator is selected in Table 1 |
SS | If Stainless Steel Indicator is selected in Table 1 |
Note: SS indicator is required for high pressure cycle applications with pressures >200 bar (3000 psi)
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.