UR209 Series Athalon® Return Line Filters product photo Primary L

UR209 Series Athalon® Return Line Filters

Features

  • Flows to 120 L/min (32 US gpm)
  • Pressures to 41 bar (600 psi)
  • Port size 1"
  • Unique Ultipleat (laid-over pleat) filter medium pack
  • Coreless, cageless element configuration
  • Pall Stress-Resistant Technology (SRT) Media
  • In-to-out filter element flow path
Please Note:
The UR209 Series is a Preferred Product Line utilizing Stress-Resistant Technology.  Please See Ordering Information for available options

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.


Contact Us
* Required

Description

Features

  • Flows to 120 L/min (32 US gpm)
  • Pressures to 41 bar (600 psi)
  • Port size 1"
  • Unique Ultipleat (laid-over pleat) filter medium pack
  • Coreless, cageless element configuration
  • Pall Stress-Resistant Technology (SRT) Media
  • In-to-out filter element flow path
Please Note:
The UR209 Series is a Preferred Product Line utilizing Stress-Resistant Technology.  Please See Ordering Information for available options

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.

Specifications

Filter Housing

  • Maximum Allowable Working Pressure:
    41 bar (600 psi)
  • Rated Fatigue Pressure:
    41 bar (600 psi)
    106 cycles per NFPA T2.06.01R2-2001
  • Typical Burst Pressure:
    130 bar (2650 psi)
  • Fluid Compatibility:
    Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids
  • Temperature Range:
    Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids
  • Materials of Construction:
    Aluminum alloy head and bowl.

Filter Element

  • Filter Element Burst Pressure:
    10 bard (150 psid)
  • Athalon™ Element Construction:
    Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design.
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 1 and 2 fluids only. Consult Sales for other fluid gas group suitability.


 
Length
Code
Overall
Length
mm (in.)
Element Removal
Clearance
mm (in.)
03 192 (7.55) 69 (2.7)
07 283 (11.16) 69 (2.7)
 






Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop

Multiply actual flow rate times factor in the table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

209 Series Filter Elements — bard/1000 L/min (psid/US gpm)

 
Length Code AZ AP AN AS AT
03 34.75 (1.907) 13.92 (0.764) 10.62 (0.583) 9.00 (0.494) 7.67 (0.421)
07 15.69 (0.861) 6.29 (0.345) 4.79 (0.263) 4.06 (0.223) 3.46 (0.190)
 

Sample ΔP calculation

UR209 Series 3" length housing with C16 (1" BSP) threaded ports using AN grade media. Operating conditions 20 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.02 x 1.2/0.9) bard (housing)
+ ((20 x 10.62/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.03 bard (housing) + 0.44 bard (element)
= 0.47 bard (6.8 psid)

Type

Housings, Vessels, or Assemblies

Ordering Information

Please select only from the following list of standard filter housing options.

Available UR209 Series Options

 
UR209HA16 03ZA1
UR209HC16 03ZA1
UR209HA16 07ZA1
UR209HC16 07ZA1
UR209HA16 03ZG1
UR209HC16 03ZG1
UR209HA16 07ZG1
UR209HC16 07ZG1
UR209HA16 03ZA1YS45
UR209HC16 03ZA1YS45
UR209HA16 07ZA1YS45
UR209HC16 07ZA1YS45
UR209HA16 03ZG1YS45
UR209HC16 03ZG1YS45
UR209HA16 07ZG1YS45
UR209HC16 07ZG1YS45
 

The specification of each filter housing part number is outlined in the tables below.

Section 1

Housing P/N: UR 209H [Table A] [Table 4] [Table 5]

Seal Kit P/N: SR210 SKZ
Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The number 1 at the end of the Housing P/N designates 1 indicator port, fitted with a plastic shipping plug.
*Other seal material options are available; Contact Pall.

Table A

 
Port & Length Options
Tables 1, 2 and 3
A1603Z
A1607Z
C1603Z
C1607Z
 

Table 1: Housing Port Options

 
Code Port Style Max. Operating Pressure
A SAE J1926 straight thread 41 bar (600 psi)
C BSP ISO 228 threads 41 bar (600 psi)
 

Table 2: Port Size

 
Code Port Style
16 1” nominal
 

Table 3: Housing Length and Seal Options

 
Code Length and Seal Material
03Z 3” nominal length, fluorocarbon seals
07Z 7” nominal length, fluorocarbon seals
 

Table 4: Bypass Valve and Service Options

 
Code Bypass Valve and Service Type
A1 1.7 bard (25 psid) bypass valve, head service 
G1 4.5 bard (65 psid) bypass valve, head service
 

Table 5: Other Options

 
Code Description
Omit Aluminum alloy head and bowl 
YS45 Anodized aluminium alloy finish for use with water glycols and HWCF
 

Section 2

Element P/N: UE 209 [Table 6] [Table 3]
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 6: Filter Element Options

 
Code ßx(c) ≥2000
based on ISO 16889
CST Rating*
AZ 3 07/04/01
AP 5 11/08/03
AN 7 13/09/04
AS 12 15/11/06
AT 25 16/14/08
 
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205

Section 3 (At least one Differential Pressure Indicator or ‘B’ type blanking plug must be ordered)

Differential Pressure Indicator P/N: RC [Table 1]  Z 091 Z [Table 2]

Note: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.

Table 7: Indicator Options

 
Code Brass Option indicator
A218M Electrical switch (SPDT) with Hirschmann connector
A218R Electrical switch (SPDT) with Hirschmann connector
with Red and Green LED indicators
A219D Visual indicator
 

 
Code Stainless Steel Option Indicator
778N Visual filter with thermal lockout
861C* Electrical Switch (SPDT) with Hirschmann connector
771B Electrical switch (SPDT) with 3-pin
 
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 8.

Table 8: Indicator Pressure Setting Options

 
Code Description
084 For ‘A’ valve option housings (1.1. bard. 16 psid)
091 For ‘G’ valve option housings (3.5. bard. 50 psid)
 

Other setting options are available; contact Pall.

Table 9: Differential Pressure Indicator Material

 
Code Pressure Setting
Omit Brass Indicator: use at operating pressures < 200 bar (3000 psi)
SS Stainless Steel Indicator: recommended for high pressure cycle applications with pressures > 200 bar (3000 psi)
 
Other setting options are available; contact Pall.