Description
Features
- Flows to 120 L/min (32 US gpm)
- Pressures to 41 bar (600 psi)
- Port size 1"
- Unique Ultipleat (laid-over pleat) filter medium pack
- Coreless, cageless element configuration
- Pall Stress-Resistant Technology (SRT) Media
- In-to-out filter element flow path
The UR209 Series is a Preferred Product Line utilizing Stress-Resistant Technology. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See ‘Ordering Information’ tab above for details of spares.
Specifications
Filter Housing
- Maximum Allowable Working Pressure:
41 bar (600 psi) - Rated Fatigue Pressure:
41 bar (600 psi)
106 cycles per NFPA T2.06.01R2-2001 - Typical Burst Pressure:
130 bar (2650 psi) - Fluid Compatibility:
Compatible with all petroleum oils, water glycols, water-oil emulsions and most synthetic hydraulic and lubrication fluids - Temperature Range:
Fluorocarbon Seals: -29 °C to 120 °C (-20 °F to 250 °F) 60 °C (140 °F) maximum in HWCF or water glycol fluids - Materials of Construction:
Aluminum alloy head and bowl.
Filter Element
- Filter Element Burst Pressure:
10 bard (150 psid) - Athalon™ Element Construction:
Inorganic fibers impregnated and bonded with epoxy resins. Polymer endcaps. Anti-static media design.
The equipment has been assessed in accordance with the guidelines laid down in The European Pressure Directive 97/23/EC and has been classified within Sound Engineering Practice S.E.P. Suitable for use with Group 1 and 2 fluids only. Consult Sales for other fluid gas group suitability.
Length Code |
Overall Length mm (in.) |
Element Removal Clearance mm (in.) |
03 | 192 (7.55) | 69 (2.7) |
07 | 283 (11.16) | 69 (2.7) |
Performance
Pressure Drop Information
Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.Element Pressure Drop
Multiply actual flow rate times factor in the table below to determine pressure drop with fluid at 32209 Series Filter Elements — bard/1000 L/min (psid /US gpm )
Length Code | AZ | AP | AN | AS | AT |
03 | 34.75 (1.907) | 13.92 (0.764) | 10.62 (0.583) | 9.00 (0.494) | 7.67 (0.421) |
07 | 15.69 (0.861) | 6.29 (0.345) | 4.79 (0.263) | 4.06 (0.223) | 3.46 (0.190) |
Sample ΔP calculation
UR209 Series 3" length housing with C16 (1" BSP) threaded ports using AN grade media. Operating conditions 20 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.Total Filter ΔP
= ΔP housing + ΔP element
= (0.02 x 1.2/0.9) bard (housing)
+ ((20 x 10.62/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.03 bard (housing) + 0.44 bard (element)
= 0.47 bard (6.8 psid)
Type
Housings, Vessels, or Assemblies
Ordering Information
Please select only from the following list of standard filter housing options.
The specification of each filter housing part number is outlined in the tables below.
Seal Kit P/N: SR210 SKZ
Other options available; contact Pall.
Available UR209 Series Options
UR209HA16 03ZA1 UR209HC16 03ZA1 UR209HA16 07ZA1 UR209HC16 07ZA1 UR209HA16 03ZG1 UR209HC16 03ZG1 UR209HA16 07ZG1 UR209HC16 07ZG1 |
UR209HA16 03ZA1YS45 UR209HC16 03ZA1YS45 UR209HA16 07ZA1YS45 UR209HC16 07ZA1YS45 UR209HA16 03ZG1YS45 UR209HC16 03ZG1YS45 UR209HA16 07ZG1YS45 UR209HC16 07ZG1YS45 |
The specification of each filter housing part number is outlined in the tables below.
Section 1
Housing P/N: UR 209H [Table A] [Table 4] [Table 5]Seal Kit P/N: SR210 SKZ
Note: Pall Athalon filter housings are supplied without filter elements or warning devices fitted. Never operate the filter unless a filter element is fitted and all warning device ports are sealed.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall. The number 1 at the end of the Housing P/N designates 1 indicator port, fitted with a plastic shipping plug.
*Other seal material options are available; Contact Pall.
Table A
Port & Length Options |
Tables 1, 2 and 3 |
A1603Z |
A1607Z |
C1603Z |
C1607Z |
Table 1: Housing Port Options
Code | Port Style | Max. Operating Pressure |
A | SAE J1926 straight thread | 41 bar (600 psi) |
C | BSP ISO 228 threads | 41 bar (600 psi) |
Table 2: Port Size
Code | Port Style |
16 | 1” nominal |
Table 3: Housing Length and Seal Options
Code | Length and Seal Material |
03Z | 3” nominal length, fluorocarbon seals |
07Z | 7” nominal length, fluorocarbon seals |
Table 4: Bypass Valve and Service Options
Code | Bypass Valve and Service Type |
A1 | 1.7 bard (25 |
G1 | 4.5 bard (65 |
Table 5: Other Options
Code | Description |
Omit | Aluminum alloy head and bowl |
YS45 | Anodized |
Section 2
Element P/N: UE 209 [Table 6] [Table 3]Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 6: Filter Element Options
Code | ßx(c) ≥2000 based on ISO 16889 |
CST Rating* |
AZ | 3 | 07/04/01 |
AP | 5 | 11/08/03 |
AN | 7 | 13/09/04 |
AS | 12 | 15/11/06 |
AT | 25 | 16/14/08 |
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205
Section 3 (At least one Differential Pressure Indicator or ‘B’ type blanking plug must be ordered)
Differential Pressure Indicator P/N: RC [Table 1] Z 091 Z [Table 2]
Note: If no differential pressure indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
Table 7: Indicator Options
Code | Brass Option indicator |
A218M | Electrical switch (SPDT) with Hirschmann connector |
A218R | Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D | Visual indicator |
Code | Stainless Steel Option Indicator |
778N | Visual filter with |
861C* | Electrical Switch (SPDT) with Hirschmann connector |
771B | Electrical switch (SPDT) with 3-pin |
Other options available; contact Pall.
* Requires YM suffix after SS code from Table 8.
Table 8: Indicator Pressure Setting Options
Code | Description |
084 | For ‘A’ valve option housings (1.1. bard. 16 |
091 | For ‘G’ valve option housings (3.5. bard. 50 |
Other setting options are available; contact Pall.
Table 9: Differential Pressure Indicator Material
Code | Pressure Setting |
Omit | Brass Indicator: use at operating pressures < 200 bar (3000 psi) |
SS | Stainless Steel Indicator: recommended for |
Other setting options are available; contact Pall.
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.