Description
Features
- Flows to 75 L/min (20 US gpm)
- Pressures to 350 bard (5,075 psid)
- Port size 3/4"
- Ultipor® III filter medium pack
- Out-to-in filter element flow path
The 9020/21/24 Series is a Preferred Product Line utilizing Ultipor® III filter medium. Please See Ordering Information for available options
All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.
Specifications
Fatigue Pressure Rating:
per NFPA T2.6.1 R2-2001 Cat C/90124 bar (1800 psi) – R length
103 bar (1500 psi) – S length
Typical Burst Pressure:
15,000 psi (1035 bar)Fluid Compatibility:
Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubricating fl uidsTemperature Range:
-29˚C to 107˚C (-20˚F to 225˚F)60˚C (140˚F) maximum in HWCF or water
Filter Element Collapse Pressure:
9020-290 psid (20 bar)9021-3000 psid (207 bar)
9024-150 psid (10 bar)
Bypass Valve Setting:
Non-bypassHousing Materials of Construction:
Aluminum head and bowlIndicator Pressure Setting:
7 bard (100 psid)Dimensional Drawings
Performance
Pressure Drop Information
Element Pressure Drop Factor
Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G. Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.9021 Series Element P factor (psid/gpm) | ||
Length |
CP |
CT |
---|---|---|
4" |
2.71 |
0.68 |
8" |
1.35 |
0.34 |
Type
Housings, Vessels, or Assemblies
Ordering Information
Please select only from the following list of standard filter housing options.
The specification of each filter housing part number is outlined in the tables below.
Available 9021 Series Options
HZ9021A12 RW1 HZ9021C12 RW1 HZ9021K12 RW1 HZ9021A12 SW1 HZ9021C12 SW1 HZ9021K12 SW1 |
The specification of each filter housing part number is outlined in the tables below.
Assembly P/N: |
H |
902 |
|
|
|
|
||||||||
|
|
Table1 |
|
Table2 |
Table3 |
Table4 |
Table5 |
Table6 |
Table7 |
Table8 |
Element P/N: |
HC 902 |
F |
|
|
|
|
||||
|
|
Table2 |
Table5 |
Table6 |
Table1 |
|
|
|
Seal Kit P/N: |
H9020SK |
|
|
|
|
|
Table 1 |
|
|
Table 1: Seal Options | |
Code | Seals |
---|---|
H | Nitrile |
Z | Fluorocarbon |
Table 2: Element Options | |
Code | Rating |
---|---|
1 | 3000 psid (high collapse) |
Table 3: Port Style Options | ||
Code | Port Style | |
---|---|---|
A | SAE J514 straight thread | |
C | BSP ISO 228 Threads | |
K | Manifold mount | |
*Contact factory for drawings.
|
Table 4: Port Size Options | |
Code |
Size |
---|---|
12 |
3/4" |
TABLE 5: FILTER ELEMENT OPTIONS | ||
CODE |
ßx 200 |
ßx(c)=1000 |
---|---|---|
CP* |
3 |
5 |
CT* |
17 |
15 |
*9021 series only.
|
Table 6: Length Options* | |
Assembly Code | Element Code** |
---|---|
R | 4 |
S | 8 |
*Use code in second column for element part no.
|
Table 7: Bypass Valve Options | |
Code | Description |
---|---|
W | Non bypass 9021 only |
Table 8: Differential Pressure Option (At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)
Differential Pressure Indicator P/N: RC [Table 8A] Z 091 Z [Table 8B]
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.
TABLE 8A: Indicator Options For applications with operating conditions less than 200 bar (3000 psi) |
|
Code |
Brass Option indicator |
---|---|
A218M |
Electrical switch (SPDT) with Hirschmann connector |
A218R |
Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators |
A219D |
Visual indicator |
For applications with operating conditions greater than 200 bar (3000 psi) |
|
Code |
Stainless Steel indicator |
---|---|
778NZ |
Visual filter with thermal lockout |
861CZ |
Electrical Switch (SPDT) with 6" leads |
861CZ* |
Electrical switch (SPDT) with Hirschmann connector |
771BZ |
Electrical switch (SPDT) with 3-pin |
Other options available; contact Pall.
|
TABLE 8B: Differential Pressure Indicator Material | |
Code |
Pressure Setting |
---|---|
Omit |
Brass Indicator: use at operating pressures < 200 bar (3000 psi) |
SS |
Stainless Steel Indicator: recommended for high pressure cycle applications with pressures > 200 bar (3000 psi) |
Other setting options are available; contact Pall. |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.