Description
Like the Pall PCM400, the new improved PCM500 uses proven mesh Blockage technology to report accurate, reliable, 3 part ISO 4406 cleanliness codes for most types of fluids, in many types of environment.
With the PCM500 you can:
- Monitor contamination levels in mineral, synthetic, or water based fluids. Results are unaffected by the presence of water, air, or dark fluids
- Get accurate, 3 part* ISO 4406 cleanliness code results in under 6 minutes and quickly take preventative action
- Upload real-time results directly to mobile devices for analysis and action
- 'Pass off' cleanliness of new builds quickly and confidently
- Protect your systems from catastrophic failure by detecting abnormal fluid cleanliness conditions quickly
The PCM500 can be permanently installed to monitor critical applications (including component test facilities) or used as a portable device for routine condition monitoring of various fluid systems
PCM500 Monitor Features
* 3 part code measured at 4 µm, 6 µm and 14 µm (c) per ISO 16889. |
For ordering and pricing information contact your local sales office or distributor Contact Us. |
Specifications
Power supply: | 90-260 VAC or integral 12 VDC Lithium Ion battery |
Battery life: | Typically 35 samples |
Temperature Range: | 5 °C to 80 °C (41 °F to 176 °F) (dependent on fluid type) |
Compatibility: | Water glycols, aqueous solutions. Petroleum and synthetic oils (hydraulic lubricating, dielectric, etc.), fuels, industrial phosphate esters. |
Seals: | Fluorocarbon |
Operating viscosity: | 1.5 to 450 cSt (30 to 2,200 SUS) |
Pressure: | 0 to 315 bar (4570 psi) max |
Monitoring Range: | ISO 4406: <11/9/7 to 23/21/17 SAE AS 4059 Table 1 Class 1 to 12 (derived from NAS 1638) SAE AS 4059 Table 2 >4 µm 1A to 12A, >6 µm 1B to 12B >14 µm 1C to 12C |
Water in Oil % RH: | ± 2% at 5 to 95% RH (PCM500W) |
Accuracy: | ± 1/2 ISO 4406 Code |
Ports: | Communication 3 x USB’s (Data Acquisition, PC Setup, Printer), RS232C (PLC Control) |
Enclosure: | IP 65 (NEMA 4) |
Weight: | 10.8 kg (23 lb) with case: 21.6kg (47.62 lb) |
Dimensions: | PCM: 400 x 260 x 250 mm (15.8 x 10.2 x 10 inches) Case: 650 x 350 x 390 mm (25.6 x 13.8 x 15.4 inches) |
The PCM500 is supplied with the default language set to English. Other languages may be accessed via the HMI menu.
For operating manuals in all languages, visit www.pall.com.
Type
Use
Ordering Information
This is a guide to the Part Numbering structure only, for specific options, please contact Pall.
PCM500 [TABLE 1] MA
Table 1: Water Sensor
Code | Description |
None | No Water Sensor fitted |
W | Water Sensor fitted |
Table 2: Connectors
Code | Description |
MA | Fluid Inlet connections:b> High Pressure: 1/4” BSP female swivel with metric, imperial or NPT test point connector Low Pressure: 1/4” BSP Female swivel fitting Power leads supplied covering UK, USA, Europe & Asia male plug formats |
Printer Kit and Accessories
PCM500-PRTA
Important: The PCM500W model is fitted with a sensor to measure water content in oil and produce a % relative humidity or PPM value. Do not use this model of PCM500 with water based fluids or permanent damage will occur.
Wheeled carry case protects the PCM500 in transit
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.