Description
The LCF Kleen-Change®-LCBN capsule filter is specifically designed to remove gelatinous material and particles from liquid crystal (LC) material, in the manufacture of thin film transistor displays. Its unique configuration and low pressure drop allows for easy venting, thus virtually eliminating the presence of air bubbles, which can cause defects during the liquid crystal one drop filling (ODF) process. Its all fluoro-polymer construction provides for excellent chemical compatibility with low extractables.
Features and Benefits
- Disposable filter capsule designed with hydraulic buffering capacity minimize defects caused by bubbles during the ODF process
- Low hold–up volume for reduced LC waste
- Filter removal rating of 0.1 μm improves yield by retaining gels and fine particles
- Excellent filter cleanliness
Specifications
Materials of Construction
Parts | Materials |
Filter Membrane | PTFE |
Hardware (capsule and core) | PFA |
Vent Cap (optional) | PFA |
End Seal | Heat Seal |
Removal Ratings | 0.1 μm | |
Maximum Operating Pressure and Temperature | 0.4 MPa (23 °C) | |
Connections | Inlet/Outlet | Vent |
1⁄8 in. Swagelok1 compatible | 1⁄8 in. Swagelok compatible | |
1 Swagelok is a trademark of Swagelok Company
Performance
Pressure Drop vs. Liquid Flow Rate (Water, 20°C)
Type
Filter Capsules
Additional Information
Dimensions
nominalWithout Vent
With Vent
Ordering Information
LCBN01FTESW2 [1]
Table 1
Code | Vent |
Blank | None |
2 | Vent, 1⁄8 in. Swagelok compatible |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.