Description
Pall's Gaskleen® PG purifier assemblies have been designed to handle process flow rates up to 1,000 slpm.
- An optional bypass manifold is available complete with isolation valves and backplate for easy mounting.
- Pall's purification materials are available in every standard configuration.
- All purifier assemblies contain an integral 316L stainless steel particle filter.
- 100% helium leak and pressure tested.
- No detectable metal contribution above background in HCl gas with HCLP material
- No detectable metal contribution above background in HBr gas with HBRP material
Specifications
Assembly Flow Rates
- PG550: 75
slpm - PG2400: 500
slpm - PG11000: 1,000
slpm
Particle Filter Options
- PG550/PG2400: 0.4 μm or 0.003 μm
- PG11000: 0.4 μm
Connections
- 1⁄4 in. or 1⁄2 in. gasket seal (VCR1 or compatible) male/male
- Inlet/outlet isolation valves (for PG11000)
Assembly Material
- Electropolished 316L SS
- <0.25 μm/<10 μin Ra internal surface finish
Operating Conditions
- Maximum operating pressure
- PG550/PG2400: 3.45 MPa/500
psig - PG11000: 1.72 MPa/250
psig
- PG550/PG2400: 3.45 MPa/500
- Maximum operating temperature:
- 100 °C/212 °F (INP, SIP, FCP, SF6P)
- 40 °C/104 °F (GEH4P, OXP, CLXP, HCLP, HBRP, CDAP)
- EU Pressure Equipment Directive: Assemblies have been evaluated for compliance with the European Union's Pressure Equipment Directive 2014/68/EU and are CE-marked.
1 VCR is a trademark of Swagelok Co.
Technical Information
Impurity Removal as Tested in Specific GasesSpecific Gas | Impurity Removal Efficiency |
Inert gases: nitrogen, argon, helium, xenon, krypton, neon | <1 ppb H2O, CO2, O2, and CO, as tested in argon and nitrogen using APIMS analyzer |
Flammable gases: silane, hydrogen, methane, ethane, cyclopropane, propane, dimethyl ether | <1 ppb H2O, CO2, O2, and CO, as tested in argon, nitrogen <1 ppb H2O, as tested in carbon monoxide using trace moisture analyzer H2O and siloxanes removed to trace levels, as tested in silane using APIMS |
Carbon monoxide | <1 ppb Ni(CO)4, and < 1 |
Fluorocarbons: fluoromethane, difluoromethane, trifluoromethane, |
<1 ppb H2O, CO2, O2, and CO, as tested in argon and nitrogen using APIMS analyzer <1 <10 ppb H2O, as tested in trifluoromethane using trace moisture analyzer and FTIR |
Germane | <1 ppb H2O, CO2, O2, and CO, as tested in argon and nitrogen using APIMS analyzer |
Sulfur hexafluoride | <1 ppb H2O, CO2, and O2, as tested in argon using APIMS |
Oxygenated gases: carbon dioxide, oxygen, nitrous oxide, clean dry air | <10 ppb H2O <1 ppb H2O, and CO2, as tested in argon using APIMS analyzer |
Chlorinated gases: boron trichloride, chlorine, trichlorosilane, dichlorosilane | <100 ppb H2O <1 ppb H2O, and CO2, as tested in argon using APIMS analyzer |
Halogenated gases: hydrogen chloride, hydrogen bromide | < 15 ppb H2O as tested in hydrogen chloride using CRDS < 50 ppb H2O as tested in hydrogen bromide using CRDS < 1 ppb H2O as tested in argon using APIMS analyzer |
Photolithography clean dry air | < 1 ppb H2O as tested in argon using APIMS analyzer < 300 ppt C4H8 as tested in argon using APIMS Analyzer < 10 ppt SO2 as tested in nitrogen using ion < 15 ppt NH3 as tested in nitrogen using ion < 1 ppt HMDSO as tested in argon using APIMS analyzer and baseline subtraction |
Unit conversion: 1 bar = 100 kilopascals
Performance
Pressure Drop vs. Gas Flow Rate
PG550 with 0.003 μm filterPG550 with 0.4 μm filter
PG2400___VMM4 with 0.003 μm filter
PG2400___VMM4 with 0.4 μm filter
PG2400___VMM8 with 0.003 μm filter
PG2400___VMM8 with 0.4 μm filter
PG11000 Series assembly
Note: For pressure drop information for a specific application, please contact Pall Microelectronics.
Lifetime Calculations
Pall AresKleenTM purification material: inert gas serviceGaskleen® PG550 purifier assembly, part # GLP9INPVMM4
Inlet pressure: 207 kPa (30 psig) contaminant challenge as H2O
Pall AresKleenTM purification material: inert gas service
Gaskleen® PG11000 purifier assembly, part # GLP110INPVFM8
Inlet pressure: 207 kPa (30 psig) contaminant challenge as H2O
Pall AresKleenTM purification material: inert gas service
Gaskleen® PG2400 purifier assembly, part # GLP24INPVMM4/VMM8
Inlet pressure: 207 kPa (30 psig) contaminant challenge as H2O
Type
Systems
Additional Information
List of Purifiable Gases
Gas Family | Material | Effluent Specification2 |
Nitrogen, argon, helium, xenon, krypton, neon | INP | <1 ppb H2O, O2, CO2 and CO |
Silane, hydrogen, methane, cyclopropane, propane, dimethyl ether | SIP | <1 ppb H2O, O2, CO2 and CO |
Carbon monoxide | SIP | <1 ppb H2O, O2, CO2, Ni(CO4), and Fe(CO)5 |
Fluoromethane, difluoromethane, |
FCP | <1 ppb H2O, O2, CO2 |
Germane | GEH4P | <1 ppb H2O, O2, CO2 |
Sulfur hexafluoride | SF6P | <1 ppb H2O, O2, CO2 |
Air, carbon dioxide, oxygen, nitrous oxide | OXP | <10 ppb H2O |
Boron trichloride, chlorine, trichlorosilane, dichlorosilane | CLXP | <100 ppb H2O |
Hydrogen chloride | HCLP | <15 ppb H2O |
Hydrogen bromide | HBRP | < 50 ppb H2O |
Photolithography clean dry air | CDAP | < 1 ppb H2O, < 300 ppt organics (as C4), < 10 ppt acid gases (as SO2), < 15 ppt basic gases (as NH3), < 1 ppt refractory compounds (as HMDSO |
2 As tested in inert gas.
Nominal Assembly Dimensions
Note: For manifold dimensions, please contact Pall Corporation.
Ordering Information
Series | Part Number3 | Description |
PG550 | GLP9xxxxFVMM4 | Purifier assembly, 75 |
GLP9xxxxFMAN | Bypass manifold with GLP9xxxFVMM4 assembly | |
GLP9xxxxFVMM4GCMAN | Gas cabinet manifold with GLP9xxxFVMM4 assembly | |
GLP9xxxxVMM4 | Purifier assembly, 75 |
|
GLP9xxxxMAN | Bypass manifold with GLP9xxxVMM4 assembly | |
GLP9xxxxVMM4GCMAN | Gas cabinet manifold with GLP9xxxVMM4 assembly | |
PG2400 | GLP24xxxxFVMM4 | Purifier assembly, 300 |
GLP24xxxxFVMM8 | Purifier assembly, 300 |
|
GLP24xxxxFMAN | Bypass manifold with GLP24xxxxFVMM8 assembly | |
GLP24xxxxVMM4 | Purifier assembly, 500 |
|
GLP24xxxxVMM8 | Purifier assembly, 500 |
|
GLP24xxxxMAN | Bypass manifold with GLP24xxxxVMM8 assembly | |
PG11000 | GLP110xxxxVFM84 | Purifier assembly, 1,000 |
GLP110xxxxMAN4 | Bypass manifold with GLP110xxxVMM8 assembly | |
3 See list of purifiable gases on page 1. Example: GLP9INPFVMM4.
4 The PG11000 stainless steel assembly (used with all GLP110 part numbers) is fabricated in accordance with the ASME BPVC Section VIII, Division 1, and has a U-stamp. If the user determines that an L-stamp is required for a lethal service application, please contact Pall Microelectronics for cost and availability.
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.