Relative filter life studies, both in the laboratory and in the field, have shown that this new construction increases service life as much as four times compared to other filters of similar appearance.
Removal ratings range from 0.6 µm (micron) to 70.0 µm absolute. Refer to Bulletin HDC 700 for more detailed information.
Operating Characteristics
The recommended maximum pressure differential for the HDC “J” Series filters is 75 psid up to 140°F (60°C) and 45 psid up to 180°F (82°C) for UNI CAP filters, and 80 psid up to 122°F (50°C) and 60 psid up to 176°F (80°C) for AB style filters.Warning: Using these filters for filtration at higher pressures or temperatures than recommended, or with fluids incompatible with polypropylene, can result in property damage or personal injury and contaminated filtrate.
Sizes
HDC II "J" Series media are available in the UNI CAP configuration. UNI CAP series pleated elements are manufactured as 2 1/2" OD by 10, 20, 30, and 40 inch long filter cartridges. Elastomeric gaskets are attached to each end cap.
Sanitary (AB Style) elements are 2 3/4" OD by 10" single open-ended constructions with an O-ring piston seal at the open end. AB style elements are also available in 20, 30, and 40 inch lengths.
Cartridge Grade |
Liquid Removal1 Rating in Microns (µm) |
Aqueous Clean Pressure | Typical Flow Rate Per 10" Module (GPM) | ||
---|---|---|---|---|---|
90% | 99.98% | AB Style | UNI CAP Style | 1-2 | |
J006 | - | <1.0* | 1.25 | 1.55 | 2-3 |
J012 | <1.0* | 1.2 | 0.22 | 0.31 | 2-3 |
J025 | <1.0* | 2.5 | 0.15 | 0.16 | 2-3 |
J045 | 1.2 | 4.5 | 0.11 | 0.12 | 2-3 |
J060 | 3.0 | 6.0 | 0.08 | 0.08 | 2-3 |
J100 | 5.4 | 10.0 | 0.06 | 0.06 | 3-5 |
J200 | 10.0 | 20.0 | 0.03 | 0.03 | 3-5 |
J400 | 22.0 | 40.0 | 0.02 | 0.02 | 5-8 |
J700 | 35 |
70.0 |
0.01 | 0.01 | 8-10 |
* Extrapolated value.
1 The test procedure used for liquid service rating is an adaptation of ANSI B93.31 - 1973, modified to determine the micron size above which particles are quantitatively removed.
2 Pressure drop in PSI per GPM water for a single 10" module. Multiply this value by the required flow to determine the total aqueous pressure drop. Next, for fluids other than water, multiply by viscosity in centipoise. If this calculated pressure drop is excessive, then divide this value by the number of 10" modules required to reduce this pressure drop to an acceptable level.
Features and Benefits
Features | Advantages | Benefits |
---|---|---|
Absolute Rated Medium | 99.98% removal efficiency | Consistent, reliable filtration |
Tapered Pore Medium | Prefilter layers | Longer service life by factors up to 4 times |
Fixed Pore Structure | No solids unloading or media migration | No contamination of filtered process fluid |
Polypropylene Medium with No Surfactants or Binders | Negligible level of extractables | Wide chemical compatibility |
Housing Information
Housings are available in polypropylene, other polymers, carbon steel. Refer to brochure SUM 200 for further details.Representative applications include:
- General Service: rinse water, reverse osmosis system pre-filtration, water–prior to and/or after demineralization.
- General Process Industries: electroplating solutions, metal etching solutions, audio and video tape coatings, automotive paints, can coatings, coil coatings, computer tape and disc coatings, photographic film manufacturing and processing.
- Chemical/Petrochemical Industries: amines for gas scrubbing, monomers, polymers, glycols, herbicides and pesticides, liquid catalysts, product polishing, photoresists, acids, bases, solvents, deep well disposal fluids.
- Film and Fiber Industries: monomers, quench water, slurry additives, delusterants, slip agents, D.I. water, solvents, spin finishes, aqueous salt solutions.
- Power Generation Industries: makeup water, laundry drain wastewater, steam generator blowdown prefilters.
- Pharmaceutical Industry: parenterals, ophthalmics, oral medications.
- Biological Industry: serum and serum fractions, tissue culture media, vaccine preparations, microbiological growth media, media makeup water, diagnostic sera.
- Cosmetics: toiletries, aftershaves, perfumes, oils, lotions, creams, ointments, shampoos, body rinses, mouthwashes.
- Fermentation Industries: liquid growth media, makeup water, intermediates, final liquid products, additives, exhaust gas, prefiltration.
- Food and Beverage Industries: potable liquids, wine, beer, soft drinks, flavors, storage tank/reactor vents, corn syrup, edible oils.
- Electronic Industries: photoresists, acids, bases, solvents, etchant gases, D.I. water prefiltration.
Ordering Information/Part Numbers
HDC II “J” Series Element Part Number:
UNI CAP Element PUY

Sanitary (AB) Style Element AB

Code![]() |
Cartridge Lengths |
1 | 10'' |
2 | 20'' |
3 | 30'' |
4 | 40'' |
Code![]() |
Grade: 99.98% Removal Rating (µm) |
J006 | <1.0* |
J012 | 1.2 |
J025 | 2.5 |
J045 | 4.5 |
J060 | 6.0 |
J100 | 10 |
J200 | 20 |
J400 | 40 |
J700 | 70 |
Code![]() |
End Fittings | |
O-Ring Fitting I.D. (In.) | O-Ring Replacement Size | |
3 | 1 1/4 | -222 (Flat end) |
7 | 1 1/2 | -226 (Finned end & bayonet lock) |
8 | 1 1/4 | -222 (Finned end) |
Code![]() |
Application Option |
Omit | Other |
P | Pharmaceutical |
Code![]() |
Gasket Option |
H13 | Buna N |
H | Viton A* |
J | Ethylene Propylene (Standard) |
Code![]() |
O-Ring Option |
H4 | Silicone (Standard) |
H | Viton A* |
J | Ethylene Propylene |
* Trademark of E.I. du Pont de Nemours and Co.