Description
Features
- Easy installation-allowing simple upgrade of existing housings — the preformed cylindrical silicone jacket is self aligning with the Pall Advanta housing bowl. It can also be used on housings with 100 mm nominal diameter bowls1
- Simple temperature adjustment — control box has a digital input from ambient to 140 °C
- Large LED display of actual temperature — measured by PT100 or Thermocouple
- Separate IP54 rated control box allows full control independent of the housing location
- Low overall installation cost — no expensive steam valves, piping and pressure regulators required
- Easy removal or access for changeout of filter elements
1Please contact Pall for further details.
Specifications
Materials of Construction
- Jacket Material: Silicone Rubber
- Insulation Material: Silicone Foam
- Housing Material: Polycarbonate
Operating Voltage
- 240 V (50 Hz) or 110 V (60 Hz)
Power Output
- 305 mm (11.8 in.) long = 300 W2 559 mm (22 in.) long = 600 W3
Maximum Temperature De-energized
- 200 °C (392 °F)
Temperature Sensor
- PT100
Thermal Cut-out Temperature Setting
- 150 °C ± 5 °C (302 °F ± 41 °F)
Testing Voltage
- 1500 VΩ
Insulation Value
- Greater than 100 MΩ
Design Standard
- EN 60519-1 and EN 60519-2
Lead Length
- 1 m (3.3 ft)
Recommended Temperature Setting Range
- Ambient to 140 °C (284 °F4)
Maximum Environmental Temperature for Controller
- 55 °C (131 °F)
Maximum Output — Current
- 7A
Over Current Protection @ 23 °C Ambient
- 4 seconds @ 12A 1 seconds @ 24A
Set Temperature Display
- 8 mm (0.31 in.) red LED display
Actual Temperature Display
- 10 mm (0.39 in.) green LED display PID (Proportional Integral Derivative control via Autotune parameters set by the user)
Protection Rating
- IP54
Design Standards
- EN61010-1
2For 10 in. (254 mm) filter elements
3For 20 in. (508 mm) filter elements
4Consult filter element specifications for maximum operating temperatures.
Applications
- Hot water tank vents-elimination of condensate to comply with current GMP
- Freeze dryer vacuum break filters — removal of residual water after steaming or integrity testing
- Filtration of ointment bases-reduction of viscosity or liquidification
- Bulk active ingredient production-temperature control to avoid crystalization during filtration
Type
Accessories and Spare Parts
Ordering Information
Advanta Trace Heater System for Housings to hold 10 in. (254 mm) Filter Elements | |
ACS0677AM | 240 V (50 Hz), UK Plug |
ACS0678AM | 250 V (50 Hz), European Plug |
ACS0685AM | Extension Lead set (10 m [33 ft]) |
Advanta Trace Heater System for Housings to hold to hold 20 in. (508 mm) Filter Elements | |
ACS0681AM | 240 V (50 Hz), UK Plug |
ACS0682AM | 250 V (50 Hz), European Plug |
ACS0685AM | Extension Lead set (10 m [33 ft]) |
US Parts and Voltages | |
ACS0798AM | 110V ac AB05 160W silicone heating jacket (5 in.) |
ACS0679AM | 110V ac AB1 300W silicone heating jacket (10 in.) |
ACS0683AM | 110V ac AB2 600W silicone heating jacket (20 in.) |
ACS0807AM | 110V ac AB3 800W silicone heating jacket (30 in.) |
Reviews
Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.
*Subject to Terms and Conditions.