Seitz® AKS4 Activated Carbon Sheets

Immobilized carbon filter media for general purpose carbon adsorption applications

Why go bulk powdered activated carbon (PAC) when you can go with Seitz AKS4 Activated Carbon Sheets? Developed to satisfy general purpose carbon adsorption applications in the food and beverage industry, the AKS4 Sheets include activated carbon within a cellulosic fibers matrix. Carbon-impregnated media with a homogeneous and consistent matrix means you can eliminate concerns over cleaning the process equipment and time and costs associated with carbon removal. Available in rectangular sheets. Other formats are available on request. 

  • High adsorption efficiency reduces overall processing time
  • Paper layer eliminates the requirement for downstream trap filtration
  • Good permeability with excellent filtrate quality
  • High economic efficiency and long service life
Seitz® AKS4 Activated Carbon Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Availability

In Stock

20041342 product photo

Product ID: 20041342
Unit of Measure
1/EA
Min Order Qty
1
Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation

Product ID: KA2DFLP16S
Unit of Measure
1/EA
Min Order Qty
1
0.2 µm
Polyvinylidene fluoride (PVDF)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes
Emflon® PFRW Kleenpak™ Capsules, 0.2µm, 174 mm, product photoFEATURED

Emflon® PFRW Kleenpak™ Capsules, 0.2µm, 174 mm,

Product ID: KA3PFRW1
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Aerosol Bacteriophage Retention
Excellent
Cage, Core, Fin End and Endcap
Polypropylene
Capsule Length (Metric mm)
174 mm
Cumulative Autoclave Steaming
50 hrs @ 140 °C
Filter Media
Double Layer PTFE
See All Attributes
Emflon® PFRW Junior Style Filter Cartridge, 0.2µm, 5.3 in, Internal Plug seal with single 116 Silicone Elastomer O-ring product photoFEATURED

Emflon® PFRW Junior Style Filter Cartridge, 0.2µm, 5.3 in, Internal Plug seal with single 116 Silicone Elastomer O-ring

Product ID: MCY4463PFRWH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PTFE
Industry-Specific Certification
W480 Food Contact
Effective Filtration Area (Metric cm²)
2800 cm²
Filter Cartridge Style
MCY-style junior
Cartridge Length (Imperial)
5.3 in
See All Attributes
Profile® II Filter Cartridges, 0.5 µm, 40 in, Single Open Ended Code 7, Silicone Elastomer O-ring product photo

Profile® II Filter Cartridges, 0.5 µm, 40 in, Single Open Ended Code 7, Silicone Elastomer O-ring

Product ID: AB4Y0057WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Filter Cartridge Style
Code 7
Maximum Differential Pressure
4 bard @ < 30° C (86◦ F)
Cage, Core, Fin End and Endcap
Polypropylene
Food Contact Compliant
Yes
See All Attributes
NXA 0.5-30U-M3S product photo

Nexis, NXA, 0.5 μm, 76.2 cm (30 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), Silicone gasket

Product ID: NXA0530UM3S
Unit of Measure
12/EA
Min Order Qty
12
0.5 micron
0.5um, 20", DOE product photo

0.5um, 20", DOE

Product ID: NXA0520U
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
NA
See All Attributes
Claris, Polypropylene, 1 micron, 9.75 inch product photo

Claris, Polypropylene, 1 micron, 9.75 inch

Product ID: CLR1975
Unit of Measure
36/EA
Min Order Qty
36
24.8 cm / 9.75 in
1 micron
NXA 1-30U-M3S product photo

NXA 1-30U-M3S

Product ID: NXA130UM3S
Unit of Measure
12/EA
Min Order Qty
12
1 micron
Nexis® T Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 20 inches, EPDM, SOE flat closed end external 222 O-rings product photo

Nexis® T Filter Cartridges, Removal Rating 1 μm, Polypropylene, Length 20 inches, EPDM, SOE flat closed end external 222 O-rings

Product ID: NXT120UM3E
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
1 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
20 in
Cartridge Length (Metric)
508 mm
Cartridge Length (Metric)
50.8 cm
Gasket / O-Ring Material
EPDM
See All Attributes
SUPRAdisc SD II EK 1 200XEK1C232SPW product photo

SUPRAdisc SD II EK 1 200XEK1C232SPW

Product ID: 7007871
Unit of Measure
1/EA
Min Order Qty
1
1. Recommended Max. Backpressure During Backwash
0.5 bar
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
Diameter (Imperial)
12 in
Diameter (Metric)
287 mm
See All Attributes
SUPRAdisc II Module, 16", Flat Gasket, Silicone Seal, Seitz EK 1 media, 5,0 m² Filter Area product photo

SUPRAdisc II Module, 16", Flat Gasket, Silicone Seal, Seitz EK 1 media, 5,0 m² Filter Area

Product ID: 7007931
Unit of Measure
1/EA
Min Order Qty
1
Adaptor End Configuration
Double Open End, Flat Gasket
1. Recommended Max. Backpressure During Backwash
0.5 bar
Plastic Material
Polypropylene
2. Recommended Max. Backpressure During Backwash
7.25 psid
Adaptor Type
Double Open End, Flat Gasket
Core Drainage Discs
Polypropylene
See All Attributes

Documents

Datasheet

  • Seitz AKS4 Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Correction of off-color, flavor and odors in distilled spirits
  • Decolorization of sweetener and sugar syrups
  • Color correction in juice and beer applications
  • Gelatin decolorization and deodorization

Specifications

Food Contact Compliance

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

  • Cellulose, powdered activated carbon, diatomaceous earth (DE, Kieselguhr)

 

Adsorption Capability

At an optimized flow rate, the probability of contact between the impurities and carbon particles is greater in carbon-impregnated sheets. This is due to process fluids more efficiently contacting carbon particles immobilized into a sheet matrix. Because of the sheet's depth (thickness), it is possible to consider the structure as being made up of a series of layers containing PAC. Having a depth of PAC and passing the fluid at an optimal flow rate through that depth enables maximum utilization of the carbon. Macro- and mesopores can generally be regarded as the highways into the carbon particle and are crucial for adsorption kinetics. Macropores are used for transport, and adsorption occurs in the meso- and micropores. Small molecules, such as methylene blue, which has a molecular weight of 319.86 Dalton, are mainly captured in micropores. Typically, over 20 g/m2 methylene blue is adsorbed.

 

Characterization

Sheet with
Protection Paper
Mass per Unit Area
g/m2
Thickness
mm
Ash
%
Water Permeability1 l/m2/min (gal/ft2/min)
No 1050 3.8 13 291 (7.2)
Yes 1050 3.8 13 100 (2.5)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

Regeneration

Depending upon the application and the adsorbed contaminants' nature, AKS series filter sheets may be regenerated by rinsing with clean water in the forward direction. However, the achievable regeneration efficiency must be determined by monitoring filtrate quality.


Sterilization and Sanitization

Method Temperature °C (°F) Maximum Differential Pressure Bar (psi) Time2 Cycle
min
Steam 125 (257) 0.5 (7.2) 20
Hot Water 90 (194) 1 (14.5) 30

1The permeability was measured under test conditions with clean water at 20 °C (68 °F) and a Δp of 1 bar (14.5 psi).