Seitz® K Series Depth Filter Sheets

High-throughput filtering capabilities and a long service life

Looking for depth filter media with unrivaled dirt removal capacities? The Seitz K Series Depth Filter Sheets provide long-lasting and high-throughput filtration you can count on time and time again. The Seitz K Filter Sheets meet the highest quality standards you've been looking for, from the selection and quality control of raw materials to applying the latest production technologies. Available in multiple grades, the homogenous and consistent media is suitable for microbial reduction and applications requiring fine, clarifying, and coarse filtration grades.

  • Includes a combination of surface, depth, and adsorptive filtration: high solids, very good permeability, excellent filtrate quality
  • Each individual filter sheet is laser etched with the sheet grade, batch number and production date for full traceability
Seitz® K Series Depth Filter Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Product Type

Accessories and Spare Parts

30-00080-03 GASKET MIST ELIM COVER product photo

30-00080-03 GASKET MIST ELIM COVER

Product ID: F1396147
Unit of Measure
1/EA
Min Order Qty
1
119095-01 product photo

119095-01

Product ID: 11909501
Unit of Measure
1/EA
Min Order Qty
1
Quick Connect Shower Adaptor - 1/2 in. male thread (Gray), with valve, with restrictor product photo

Quick Connect Shower Adaptor - 1/2 in. male thread (Gray), with valve, with restrictor

Product ID: SHO1/2MVR
Unit of Measure
1/EA
Min Order Qty
1
Packaging Info
1 pkg
Quick Connect Shower Adaptor - 1/2 in. male thread (Black), with valve, without restrictor product photo

Quick Connect Shower Adaptor - 1/2 in. male thread (Black), with valve, without restrictor

Product ID: SHO1/2MVN
Unit of Measure
1/EA
Min Order Qty
1
Quick Connect Tap Adaptor - 1/2 in. female thread, non-valved product photo

Quick Connect Tap Adaptor - 1/2 in. female thread, non-valved

Product ID: TAP1/2FN
Unit of Measure
1/EA
Min Order Qty
1
Packaging Info
1 pkg
F1376202 1 quart oil for vacuum pump product photo

F1376202 1 quart oil for vacuum pump

Product ID: F1376202
Unit of Measure
1/EA
Min Order Qty
1
PFD-HA 1.3125-12 UNJ-3B product photo

PFD-HA 1.3125-12 UNJ-3B

Product ID: F1330421
Unit of Measure
1/EA
Min Order Qty
1
MAHW1-1016FD product photo

MAHW1-1016FD

Product ID: P2240684
Unit of Measure
1/EA
Min Order Qty
1
1198559,BUNA-N,-40--110 product photo

1198559,BUNA-N,-40--110

Product ID: 1198559
Unit of Measure
1/EA
Min Order Qty
1
SEAL KIT ( 1371785 ) product photo

SEAL KIT ( 1371785 )

Product ID: HH8924SKYN91
Unit of Measure
1/EA
Min Order Qty
1
O-RING FEP 18.64 I/D X 3.53 product photo

O-RING FEP 18.64 I/D X 3.53

Product ID: PDC81036P
Unit of Measure
1/EA
Min Order Qty
1
8300 GLASS SIGHT HC8300-1D17 product photo

8300 GLASS SIGHT HC8300-1D17

Product ID: F1124467
Unit of Measure
1/EA
Min Order Qty
1

Documents

Datasheet

  • Seitz K Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Seitz EKS, Seitz EK 1, Seitz EK, Seitz KS 50, Seitz KS 80 

Microorganism reduction and yeast removal in wine, final filtration of juice and juice concentrate, microorganism reduction in sugar syrups and microorganism reduction in enzyme solutions

 

  • Seitz K 100, Seitz K 150, Seitz K 200, Seitz K 250, Seitz K 300

Polishing of wine, prefiltration of juice prior to final membrane filtration and haze removal in apple juice

 

  • Seitz K 700, Seitz K 800, Seitz K 900

Wine clarification, particle removal from fruit juice and tea-based drinks, prefiltration of juice concentrate, olive oil polishing, enzyme solution and sweetener clarification

Specifications

Relative Retention Rating1

1Measured under laboratory test conditions. Removal performance of filter sheets is nominal and dependent on process conditions. There is no standardized method among manufacturers for its characterization.

 

Food Contact Compliance

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

Cellulose, diatomaceous earth (DE, Kieselguhr), perlite

 

Characterization:

Grade

Mass per 

Unit Area

g/m2

Thickness

mm

Ash 

%

Water

Permeability2

L/m2/min

(gal/ft2/min)

EKS 1400 3.7 58 29 (0.7)
EK 1 1450 3.8 51 41 (1)
EK 1400 3.8 46 68 (1.7)
KS 50 1350 3.7 46 93 (2.3)
KS 80 1350 3.7 46 113 (2.8)
K 100 1350 3.7 46 146 (3.6)
K 150 1350 3.9 46 185 (4.6)
K 200 1350 3.9 46 213 (5.2)
K 250 1250 4 46 510 (12.5)
K 300 1250 4.2 46 785 (19.3)
K 700 1250 4.1 46 925 (22.8)
K 800 1250 4.1 46 1275 (31.4)
K 900 1200 4.3 46 1700 (41.8)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

2The permeability was measured under test conditions with clean water at 20 °C (68 °F) and a Δp of 1 bar (14.5 psi).

 

Regeneration

Seitz K series filter sheets may be rinsed with clean water (in the forward or reverse direction3) to increase throughput and optimize economic efficiency. Optimal regeneration of filter sheets installed in a plate and frame filter may be achieved with serial rinses of warm water followed by hot water. An example protocol is shown below.

 

  1. Rinse with warm water 60 °C (140 °F) for 15 minutes
  2. Rinse with hot water 70 – 80 °C (158 – 176 °F) for 8 – 10 minutes

 

The rinse flow rate should be equivalent to the filtration flow rate with a back pressure of 0.5 –1 bar (7.2 –14.5 psi).

 

3When rinsing in the reverse flow direction, it is critical to control particulate and microbial levels in the rinse water so that the sheet's filtrate side is not contaminated. Water used for reverse flow flushes should be particle-free, and if the filter will not be sterilized prior to re-use the water should be free of microbes. Backwashing should be in a diagonal direction from outlet to inlet in a plate and frame filter.

 

Sterilization and Sanitation

Method Temperature °C (°F) Maximum Differential Pressure bar (psi) Time4/Cycle min
Steam 125 (257) 0.5 (7.2) 20
Hot Water 90 (194) 1 (14.5) 30

4The actual time required may vary as a function of the process conditions.

 

Filtration Guidelines5

For achieving optimal filtrate quality, the following flow velocities and differential pressures should not be exceeded:

Grade Description

Flow Velocity

L / m2/h

(gal/ft2/ h)

Maximum

Differential

Pressure-bar (psi)

EKS, EK 1, EK, KS 50, KS 80 Fine Filtration 525 (12.9) 1.5 (21.8)
K 100, K 150, K 200, K 250, K 300 Polishing Filtration 850 (20.9) 3 (43.5)
K 700, K 800, K 900 Coarse Filtration 850 (20.9) 3 (43.5)

5Please contact Pall for recommendations on your specific filtration process as results may vary by product, pre-filtration and filtration conditions.

 

For additional operating guidelines, including rinsing of sheets prior to use, please refer to instructions provided by Pall.

 

Quality

  • Seitz Filter Sheets are produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System