Seitz® IR Series Depth Filter Sheets

Reduce your risk of precipitation in distilled spirits

Seitz Ion Reduced (IR) Depth Filter Sheets are part of the IR series of products. These media undergo a proprietary treatment that results in extremely low extractable ions, making them the ideal solution for distilled spirit applications. The homogenous and consistent media include surface, depth and adsorptive filtration for high solids retention, which gives you high solids retention, very good permeability and excellent filtrate quality. Available in multiple grades. 

  • High economic efficiency due to a long service life
  • Each individual filter sheet is laser etched with the sheet grade, batch number and production date for full traceability

Order Products

Brand

Nexis®

Featured product

false

NXA 0.5-10U product photo

Nexis, NXA, 0.5 μm, 25.4 cm (10 in), DOE industrial (no end caps)

Product ID: NXA0510U
Unit of Measure
30/EA
Min Order Qty
30
0.5 micron
NXA 0.5-20U-H21 product photo

Nexis, NXA, 0.5 μm, 50.8 cm (20 in), DOE, Santoprene gasket seal

Product ID: NXA0520UH21
Unit of Measure
12/EA
Min Order Qty
12
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, silicone, SOE fin end external 222 O-rings product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, silicone, SOE fin end external 222 O-rings

Product ID: NXA0530UM8S
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
Silicone
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, DOE Santoprene gasket seal product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 30 inches, DOE Santoprene gasket seal

Product ID: NXA0530UH21
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
30 in
Cartridge Length (Metric)
762 mm
Cartridge Length (Metric)
76.2 cm
Gasket / O-Ring Material
NA
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 40 inches, Nitrile product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 40 inches, Nitrile

Product ID: NXA0540UDOEN
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Nitrile
See All Attributes
NXA 0.5-30U-M7S product photo

Nexis, NXA, 0.5 μm, 76.2 cm (30 in), SOE fin end, external 226 O-rings (retrofits other manufacturers’ Code 7), Silicone gasket

Product ID: NXA0530UM7S
Unit of Measure
12/EA
Min Order Qty
12
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 40 inches, silicone, SOE fin end external 226 O-rings product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 40 inches, silicone, SOE fin end external 226 O-rings

Product ID: NXA0540UM7S
Unit of Measure
12/EA
Min Order Qty
12
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Silicone
See All Attributes
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 40 inches, silicone, SOE flat closed end external 222 O-rings product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, Length 40 inches, silicone, SOE flat closed end external 222 O-rings

Product ID: NXA0540UM3S
Unit of Measure
24/EA
Min Order Qty
24
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
40 in
Cartridge Length (Metric)
1016 mm
Cartridge Length (Metric)
101.6 cm
Gasket / O-Ring Material
Silicone
See All Attributes
NXA 0.5-30U-M3S product photo

Nexis, NXA, 0.5 μm, 76.2 cm (30 in), SOE flat closed end, external 222 O-rings (retrofits other manufacturers’ Code 0), Silicone gasket

Product ID: NXA0530UM3S
Unit of Measure
12/EA
Min Order Qty
12
0.5 micron
NXA 0.5-9.75U-H21 product photo

Nexis, NXA, 0.5 μm, 24.8 cm (9.75 in), DOE, Santoprene gasket seal

Product ID: NXA05975UH21
Unit of Measure
30/EA
Min Order Qty
30
0.5 micron
Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, EPDM product photo

Nexis® A Series Filter Cartridges, Removal Rating 0.5 μm, Polypropylene, EPDM

Product ID: NXA05TFUDOEE47
Unit of Measure
10/EA
Min Order Qty
10
Removal Rating
0.5 µm
Membrane Material
Polypropylene
Gasket / O-Ring Material
EPDM
End Configuration Code
DOE
End Configuration
DOE - DOE with elastomer gasket seals and end caps
Cartridge Type
NXA
See All Attributes
NXT 0.5 -10U product photo

Nexis, NXT, 0.5 μm, 25.4 cm (10 in), DOE industrial (no end caps)

Product ID: NXT0510U
Unit of Measure
30/EA
Min Order Qty
30
0.5 micron

Documents

Datasheet

  • Seitz IR Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Seitz KS 50 IR 

Polishing filtration in white spirits

 

  • Seitz K 100 IR

Chill filtration of white spirits

 

  • Seitz K 250 IR 

Chill filtration of tannin-containing spirits or white spirits high in fatty acids

 

  • Seitz K 800 IR 

Particle removal

Specifications

Relative Retention Rating1

Food Contact Compliance

  • Food contact compliant filters are available. Please consult the Declarations of Compliance for applicable part numbers at the links below.
  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

Cellulose, diatomaceous earth (DE, Kieselguhr), perlite

 

Characterization

Grade Mass per Unit
Area g/m2
Thickness
mm
Ash
%
Water Permeability2
L/m2/min
(gal/ft2/min)
KS 50 IR 1350 3.7 46 93 (2.3)
K 100 IR 1400 4.3 51 187 (4.6)
K 250 IR 1250 4 46 510 (12.5)
K 800 IR 1250 4.1 46 1275 (31.4)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

2The permeability was measured under test conditions with clean water at 20° C (68° F) and a Δp of 1 bar (14.5 psi).

 

The diagram below illustrates the release of calcium and magnesium from the comparable standard filter sheet K100 and K100 IR into whisky during filtration.

The following total calcium and magnesium release per m2 filter sheet at a flow velocity of 500 L/m2/h (12.3 gal/ft2/h) was calculated during this filtration run:

Sheet Calcium mg/m2 (%) Magnesium mg/m2(%)
K 1003 667 (100) 192 (100
K 100 IR 146 (22) 68 (35)

3The K 100 is the comparable standard sheet to the K 100 IR with regard to the material composition.

 

Quality

  • Filter sheets produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

 

The use of ion-reduced water (deionized water) is highly recommended for the reconstitution of distillates to single strength.

 

To prevent dilution upon installation, a water rinse is not recommended for sheet filters used in the spirits industry. Product circulation for 10 to 15 minutes back to the feed tank helps distribute ions extracted at the beginning of filtration to the entire batch, reducing precipitation's overall risk.

 

Filtration Guidelines4

As the filtrate quality can be impacted by the filtration flow rate, the following table provides flux rate guidelines.

Application Flow Velocity L/m2/h (gph/ft2)
Particle filtration of brown spirits 500 – 700 (12.3 – 17.2)
Particle filtration white spirits 700 – 900 (17.2 – 22.1)
Chill filtration of brown spirits and white spirits high in fatty acids 250 – 400 (6.1 – 9.8)
Chill filtration of white spirits 400 – 600 (9.8 – 14.7)

4 Please contact Pall for recommendations on your specific filtration process as results may vary by product, pre-filtration and filtration conditions.

 

For additional operating guidelines, please refer to the instructions provided by Pall.