Seitz® IR Series Depth Filter Sheets

Reduce your risk of precipitation in distilled spirits

Seitz Ion Reduced (IR) Depth Filter Sheets are part of the IR series of products. These media undergo a proprietary treatment that results in extremely low extractable ions, making them the ideal solution for distilled spirit applications. The homogenous and consistent media include surface, depth and adsorptive filtration for high solids retention, which gives you high solids retention, very good permeability and excellent filtrate quality. Available in multiple grades. 

  • High economic efficiency due to a long service life
  • Each individual filter sheet is laser etched with the sheet grade, batch number and production date for full traceability

Order Products

Featured product

false

Element Series

HC2286

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 15in 38.1cm (REPLACED BY HC2286FRN15H50) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 15in 38.1cm (REPLACED BY HC2286FRN15H50)

Product ID: HC2286FCN15H50X321
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2286
Filter Removal Rating
7 micron (Beta 1000)
Nominal Length (Imperial)
15 in
Seal Material
Nitrile

This product is currently not available. Please contact us for more information.

Red1000 Glass Fiber 5 micron (Beta 1000) Fluorocarbon 12in 30.48cm length product photo

Element Coralon HC2286FCP12Z50

Product ID: HC2286FCP12Z50
Unit of Measure
3/EA
Min Order Qty
3
Element Series
HC2286
Nominal Length (Imperial)
12 in
Seal Material
Fluorocarbon
Red1000 Glass Fiber 12 micron (Beta 1000) Fluorocarbon 15in 38.1cm product photo

Element Coralon HC2286FCS15Z50

Product ID: HC2286FCS15Z50
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 1000)
Nominal Length (Imperial)
15 in
Seal Material
Fluorocarbon
Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 15in 38.1cm (REPLACED BY HC2286FRS15H50) product photo

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 15in 38.1cm (REPLACED BY HC2286FRS15H50)

Product ID: HC2286FKS15H50
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 1000)
Nominal Length (Imperial)
15 in
Seal Material
Nitrile
Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 30in 76.2cm (REPLACED BY HC2286FRT30H50) product photo

Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 30in 76.2cm (REPLACED BY HC2286FRT30H50)

Product ID: HC2286FKT30H50
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2286
Nominal Length (Imperial)
30 in
Seal Material
Nitrile

This product is currently not available. Please contact us for more information.

Supralon GlassFiber 12 micron (Beta 2000) Nitrile 15in 38.1cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 15 Inches

Product ID: HC2286FRS15H50YT
Unit of Measure
6/EA
Min Order Qty
6
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
15 in
Seal Material
Nitrile
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 12in 30.48cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 12 Inches

Product ID: HC2286FRS12Z50
Unit of Measure
3/EA
Min Order Qty
3
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
12 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Nitrile 17in 43.18cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 17 Inches

Product ID: HC2286FRS17H50X373
Unit of Measure
6/EA
Min Order Qty
6
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
17 in
Seal Material
Nitrile
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 12in 30.48cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 12 Inches

Product ID: HC2286FRS12Z
Unit of Measure
3/EA
Min Order Qty
3
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
12 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 15in 38.1cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 15 Inches

Product ID: HC2286FRS15Z50
Unit of Measure
6/EA
Min Order Qty
6
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
15 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 15in 38.1cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 15 Inches

Product ID: HC2286FRS15Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
15 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Nitrile 30in 76.2cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 30 Inches

Product ID: HC2286FRS30H82
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2286
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
30 in
Seal Material
Nitrile

Documents

Datasheet

  • Seitz IR Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Seitz KS 50 IR 

Polishing filtration in white spirits

 

  • Seitz K 100 IR

Chill filtration of white spirits

 

  • Seitz K 250 IR 

Chill filtration of tannin-containing spirits or white spirits high in fatty acids

 

  • Seitz K 800 IR 

Particle removal

Specifications

Relative Retention Rating1

Food Contact Compliance

  • Food contact compliant filters are available. Please consult the Declarations of Compliance for applicable part numbers at the links below.
  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

Cellulose, diatomaceous earth (DE, Kieselguhr), perlite

 

Characterization

Grade Mass per Unit
Area g/m2
Thickness
mm
Ash
%
Water Permeability2
L/m2/min
(gal/ft2/min)
KS 50 IR 1350 3.7 46 93 (2.3)
K 100 IR 1400 4.3 51 187 (4.6)
K 250 IR 1250 4 46 510 (12.5)
K 800 IR 1250 4.1 46 1275 (31.4)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

2The permeability was measured under test conditions with clean water at 20° C (68° F) and a Δp of 1 bar (14.5 psi).

 

The diagram below illustrates the release of calcium and magnesium from the comparable standard filter sheet K100 and K100 IR into whisky during filtration.

The following total calcium and magnesium release per m2 filter sheet at a flow velocity of 500 L/m2/h (12.3 gal/ft2/h) was calculated during this filtration run:

Sheet Calcium mg/m2 (%) Magnesium mg/m2(%)
K 1003 667 (100) 192 (100
K 100 IR 146 (22) 68 (35)

3The K 100 is the comparable standard sheet to the K 100 IR with regard to the material composition.

 

Quality

  • Filter sheets produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

 

The use of ion-reduced water (deionized water) is highly recommended for the reconstitution of distillates to single strength.

 

To prevent dilution upon installation, a water rinse is not recommended for sheet filters used in the spirits industry. Product circulation for 10 to 15 minutes back to the feed tank helps distribute ions extracted at the beginning of filtration to the entire batch, reducing precipitation's overall risk.

 

Filtration Guidelines4

As the filtrate quality can be impacted by the filtration flow rate, the following table provides flux rate guidelines.

Application Flow Velocity L/m2/h (gph/ft2)
Particle filtration of brown spirits 500 – 700 (12.3 – 17.2)
Particle filtration white spirits 700 – 900 (17.2 – 22.1)
Chill filtration of brown spirits and white spirits high in fatty acids 250 – 400 (6.1 – 9.8)
Chill filtration of white spirits 400 – 600 (9.8 – 14.7)

4 Please contact Pall for recommendations on your specific filtration process as results may vary by product, pre-filtration and filtration conditions.

 

For additional operating guidelines, please refer to the instructions provided by Pall.