Seitz® IR Series Depth Filter Sheets

Reduce your risk of precipitation in distilled spirits

Seitz Ion Reduced (IR) Depth Filter Sheets are part of the IR series of products. These media undergo a proprietary treatment that results in extremely low extractable ions, making them the ideal solution for distilled spirit applications. The homogenous and consistent media include surface, depth and adsorptive filtration for high solids retention, which gives you high solids retention, very good permeability and excellent filtrate quality. Available in multiple grades. 

  • High economic efficiency due to a long service life
  • Each individual filter sheet is laser etched with the sheet grade, batch number and production date for full traceability

Order Products

Featured product

false

Family

Red1000

Red1000 Glass Fiber 5 micron (Beta 1000) Nitrile 4in 10.16cm product photo

Element Coralon HC2196FCP4H50

Product ID: HC2196FCP4H50
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2196
Filter Removal Rating
5 Micron, Beta 1000
Nominal Length (Imperial)
4 in
OEM 1
Baldwin
OEM 2
EPE
OEM 3
Hydac
See All Attributes
Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2196FRN4H50) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2196FRN4H50)

Product ID: HC2196FKN4H50
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2196
Filter Removal Rating
7 micron (Beta 1000)
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2216FRS4Z) product photo

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2216FRS4Z)

Product ID: HC2216FKS4H
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2216
Filter Removal Rating
12 micron (Beta 1000)
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 7 micron (Beta 1000) Fluorocarbon 4in 10.16cm (REPLACED BY HC2217FHN4Z) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Fluorocarbon 4in 10.16cm (REPLACED BY HC2217FHN4Z)

Product ID: HC2217FCN4Z
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2217
Nominal Length (Imperial)
4 in
Seal Material
Fluorocarbon
Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2217FHT14Z) product photo

Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2217FHT14Z)

Product ID: HC2217FCT14H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2217
Filter Removal Rating
22 micron, Beta 1000
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 5 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2217FHP4Z) product photo

Red1000 Glass Fiber 5 micron (Beta 1000) Nitrile 4in 10.16cm (REPLACED BY HC2217FHP4Z)

Product ID: HC2217FDP4H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2217
Filter Removal Rating
5 micron (Beta 1000)
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 4in 10.16cm length (REPLACED BY HC2218FRS4Z) product photo

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 4in 10.16cm length (REPLACED BY HC2218FRS4Z)

Product ID: HC2218FKS4H
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2218
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 4in 10.16cm length product photo

Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 4in 10.16cm length

Product ID: HC2226FCS4H100
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2226
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 4in 10.16cm length (REPLACED BY HC2226FRN4H50) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 4in 10.16cm length (REPLACED BY HC2226FRN4H50)

Product ID: HC2226FKN4H50
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2226
Nominal Length (Imperial)
4 in
Seal Material
Nitrile
Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 4in 10.16cm product photo

Element Coralon HC2295FCT14H

Product ID: HC2295FCT14H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2295
Filter Removal Rating
22 micron, Beta 1000
Nominal Length (Imperial)
14 in
OEM 1
Hypro
OEM 2 Part Number
Hypro HP95RNL14-22EB
OEM 3 Part Number
Hypro HP95RNL14-25MB
See All Attributes
Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 3in 7.62cm (REPLACED BY HC0896FHN3Z) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 3in 7.62cm (REPLACED BY HC0896FHN3Z)

Product ID: HC0896FDN3H
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC0896
Filter Removal Rating
7 micron (Beta 1000)
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Red1000 Glass Fiber 25 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0896FHT3Z) product photo

Red1000 Glass Fiber 25 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0896FHT3Z)

Product ID: HC0896FDT3H
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC0896
Nominal Length (Imperial)
3 in
Seal Material
Nitrile

Documents

Datasheet

  • Seitz IR Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Seitz KS 50 IR 

Polishing filtration in white spirits

 

  • Seitz K 100 IR

Chill filtration of white spirits

 

  • Seitz K 250 IR 

Chill filtration of tannin-containing spirits or white spirits high in fatty acids

 

  • Seitz K 800 IR 

Particle removal

Specifications

Relative Retention Rating1

Food Contact Compliance

  • Food contact compliant filters are available. Please consult the Declarations of Compliance for applicable part numbers at the links below.
  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

Cellulose, diatomaceous earth (DE, Kieselguhr), perlite

 

Characterization

Grade Mass per Unit
Area g/m2
Thickness
mm
Ash
%
Water Permeability2
L/m2/min
(gal/ft2/min)
KS 50 IR 1350 3.7 46 93 (2.3)
K 100 IR 1400 4.3 51 187 (4.6)
K 250 IR 1250 4 46 510 (12.5)
K 800 IR 1250 4.1 46 1275 (31.4)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

2The permeability was measured under test conditions with clean water at 20° C (68° F) and a Δp of 1 bar (14.5 psi).

 

The diagram below illustrates the release of calcium and magnesium from the comparable standard filter sheet K100 and K100 IR into whisky during filtration.

The following total calcium and magnesium release per m2 filter sheet at a flow velocity of 500 L/m2/h (12.3 gal/ft2/h) was calculated during this filtration run:

Sheet Calcium mg/m2 (%) Magnesium mg/m2(%)
K 1003 667 (100) 192 (100
K 100 IR 146 (22) 68 (35)

3The K 100 is the comparable standard sheet to the K 100 IR with regard to the material composition.

 

Quality

  • Filter sheets produced in a controlled environment
  • Manufactured according to ISO 9001:2015 certified Quality Management System

 

The use of ion-reduced water (deionized water) is highly recommended for the reconstitution of distillates to single strength.

 

To prevent dilution upon installation, a water rinse is not recommended for sheet filters used in the spirits industry. Product circulation for 10 to 15 minutes back to the feed tank helps distribute ions extracted at the beginning of filtration to the entire batch, reducing precipitation's overall risk.

 

Filtration Guidelines4

As the filtrate quality can be impacted by the filtration flow rate, the following table provides flux rate guidelines.

Application Flow Velocity L/m2/h (gph/ft2)
Particle filtration of brown spirits 500 – 700 (12.3 – 17.2)
Particle filtration white spirits 700 – 900 (17.2 – 22.1)
Chill filtration of brown spirits and white spirits high in fatty acids 250 – 400 (6.1 – 9.8)
Chill filtration of white spirits 400 – 600 (9.8 – 14.7)

4 Please contact Pall for recommendations on your specific filtration process as results may vary by product, pre-filtration and filtration conditions.

 

For additional operating guidelines, please refer to the instructions provided by Pall.