Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.

Order Products

Industries

Industrial Manufacturing

Product Type

Accessories and Spare Parts

30-00080-03 GASKET MIST ELIM COVER product photo

30-00080-03 GASKET MIST ELIM COVER

Product ID: F1396147
Unit of Measure
1/EA
Min Order Qty
1
119095-01 product photo

119095-01

Product ID: 11909501
Unit of Measure
1/EA
Min Order Qty
1
F1376202 1 quart oil for vacuum pump product photo

F1376202 1 quart oil for vacuum pump

Product ID: F1376202
Unit of Measure
1/EA
Min Order Qty
1
PFD-HA 1.3125-12 UNJ-3B product photo

PFD-HA 1.3125-12 UNJ-3B

Product ID: F1330421
Unit of Measure
1/EA
Min Order Qty
1
MAHW1-1016FD product photo

MAHW1-1016FD

Product ID: P2240684
Unit of Measure
1/EA
Min Order Qty
1
1198559,BUNA-N,-40--110 product photo

1198559,BUNA-N,-40--110

Product ID: 1198559
Unit of Measure
1/EA
Min Order Qty
1
SEAL KIT ( 1371785 ) product photo

SEAL KIT ( 1371785 )

Product ID: HH8924SKYN91
Unit of Measure
1/EA
Min Order Qty
1
8300 GLASS SIGHT HC8300-1D17 product photo

8300 GLASS SIGHT HC8300-1D17

Product ID: F1124467
Unit of Measure
1/EA
Min Order Qty
1
O-RING 23.00 OD X 22.45 ID product photo

O-RING 23.00 OD X 22.45 ID

Product ID: T10540073
Unit of Measure
1/EA
Min Order Qty
1
ORG 222 VIT A product photo

ORG 222 VIT A

Product ID: T10540245
Unit of Measure
1/EA
Min Order Qty
1
ORG VITON A #226 product photo

ORG VITON A #226

Product ID: T10540272
Unit of Measure
1/EA
Min Order Qty
1
UNI-SEAL 30 316 W/SHROUD product photo

UNI-SEAL 30 316 W/SHROUD

Product ID: T10677032
Unit of Measure
1/EA
Min Order Qty
1

Documents

Datasheet

  • PERMAdur S

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes