Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.

Order Products

Nominal Length (Imperial)

10 in

Emflon® PFRW Filter Cartridge, 0.2µm, 10 in, Single open ended Code 7, Silicone Elastomer O-ring product photoFEATURED

Emflon® PFRW Filter Cartridge, 0.2µm, 10 in, Single open ended Code 7, Silicone Elastomer O-ring

Product ID: AB1PFR7WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PTFE
Effective Filtration Area (Metric cm²)
8000 cm²
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
See All Attributes
Fuente II Filter Cartridge, 10 in,single open end code 7, Silicone Elastomer O-ring product photo

Fuente II Filter Cartridge, 10 in,single open end code 7, Silicone Elastomer O-ring

Product ID: AB1FFN7WH4
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Double Layer PES, with built in pre-filtration
Effective Filtration Area (Metric m²)
1.04 m²
Filter Cartridge Style
Code 7
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
See All Attributes
Claris Filter Cartridge, 10 µm, 10 in, Double Open Ended with no endcaps product photo

Claris Filter Cartridge, 10 µm, 10 in, Double Open Ended with no endcaps

Product ID: CLR1010W480
Unit of Measure
36/EA
Min Order Qty
36
Removal Rating
10 µm
Membrane Material
Polypropylene
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
Gasket O-Ring Code
Blank
See All Attributes
Red1000 Glass Fiber 12 micron (Beta 1000) Nitrile 10in 25.4cm product photo

Element Coralon HC2236FCS10

Product ID: HC2236FCS10
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2236
Filter Removal Rating
12 micron, Beta 1000
Nominal Length (Imperial)
10 in
OEM 1
EPE
OEM 2
Hydac
OEM 3
Hypro
See All Attributes
Red1000 Glass Fiber 5 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC2246FRP10H50) product photo

Red1000 Glass Fiber 5 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC2246FRP10H50)

Product ID: HC2246FKP10H50
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2246
Filter Removal Rating
5 micron (Beta 1000)
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC2246FRN10H50) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC2246FRN10H50)

Product ID: HC2246FKN10H50
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC2246
Filter Removal Rating
7 micron (Beta 1000)
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Ultipor III Glass Fiber 12 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC4801FHS10Z) product photo

Ultipor III Glass Fiber 12 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC4801FHS10Z)

Product ID: HC4801FDS10H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC4801
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC4901FHT10Z) product photo

Red1000 Glass Fiber 22 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC4901FHT10Z)

Product ID: HC4901FCT10H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC4901
Filter Removal Rating
22 micron, Beta 1000
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Ultipor III Glass Fiber 12 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC6100FRS10Z) product photo

Ultipor III Glass Fiber 12 micron (Beta 1000) Nitrile 10in 25.4cm (REPLACED BY HC6100FRS10Z)

Product ID: HC6100FKS10H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC6100
Filter Removal Rating
12 micron (Beta 1000)
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Supralon GlassFiber 19 micron (Beta 2000) Nitrile 10in 25.4 cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 19 μm, GlassFiber, Length 10 Inches

Product ID: 2.4419.800.0
Unit of Measure
1/EA
Min Order Qty
1
Filter Removal Rating
19 micron (Beta 2000)
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Supralon GlassFiber 5 micron (Beta 2000) Nitrile 10in 25.4cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 5 μm, GlassFiber, Length 10 inches

Product ID: HA522602
Unit of Measure
6/EA
Min Order Qty
6
Element Series
HA522
Filter Removal Rating
5 micron (Beta 2000)
Nominal Length (Imperial)
10 in
Seal Material
Nitrile
Supralon GlassFiber 7 micron (Beta 2000) Nitrile 10in 25.4cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 7 μm, GlassFiber, Length 10 Inches

Product ID: HC2233FRN10HCN
Unit of Measure
12/EA
Min Order Qty
12
Element Series
HC2233
Filter Removal Rating
7 micron (Beta 2000)
Nominal Length (Imperial)
10 in
Seal Material
Nitrile

Documents

Datasheet

  • PERMAdur S

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes