Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.

Order Products

Nominal Length (Imperial)

3 in

Ultipor III Glass Fiber 5 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0030FRP3Z) product photo

Ultipor III Glass Fiber 5 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0030FRP3Z)

Product ID: HC0030FDP3H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC0030
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Ultipor III Glass Fiber 7 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0030FRN3Z) product photo

Ultipor III Glass Fiber 7 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0030FRN3Z)

Product ID: HC0030FDN3H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC0030
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Ultipor III Glass Fiber 12 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0030FRS3Z) product photo

Ultipor III Glass Fiber 12 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0030FRS3Z)

Product ID: HC0030FDS3H
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC0030
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 3in 7.62cm (REPLACED BY HC0896FHN3Z) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Nitrile 3in 7.62cm (REPLACED BY HC0896FHN3Z)

Product ID: HC0896FDN3H
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC0896
Filter Removal Rating
7 micron (Beta 1000)
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Red1000 Glass Fiber 25 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0896FHT3Z) product photo

Red1000 Glass Fiber 25 micron (Beta 1000) Nitrile 3in 7.62cm length (REPLACED BY HC0896FHT3Z)

Product ID: HC0896FDT3H
Unit of Measure
1/EA
Min Order Qty
6
Element Series
HC0896
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Red1000 Glass Fiber 12 micron (Beta 1000) Fluorocarbon 3in 7.62cm product photo

HC2206FCS3Z ELEMENT

Product ID: HC2206FCS3Z
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2206
Filter Removal Rating
12 micron, Beta 1000
Nominal Length (Imperial)
3 in
OEM 1
EPE
OEM 2
Hydac
OEM 3
Hypro
See All Attributes
Red1000 Glass Fiber 7 micron (Beta 1000) Fluorocarbon 3in 7.62cm (REPLACED BY HC2206FRN3Z) product photo

Red1000 Glass Fiber 7 micron (Beta 1000) Fluorocarbon 3in 7.62cm (REPLACED BY HC2206FRN3Z)

Product ID: HC2206FKN3Z
Unit of Measure
1/EA
Min Order Qty
1
Element Series
HC2206
Filter Removal Rating
7 micron (Beta 1000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 3in 7.62cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 3 inches

Product ID: HC0030FRS3Z
Unit of Measure
12/EA
Min Order Qty
12
Element Series
HC0030
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 3in 7.62cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 3 inches

Product ID: HC0465FRS3Z
Unit of Measure
12/EA
Min Order Qty
12
Element Series
HC0465
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 3in 7.62cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 3 inches

Product ID: HC0896FHS3Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
HC0896
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 3in 7.62cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 3 Inches

Product ID: HC2206FRS3Z
Unit of Measure
12/EA
Min Order Qty
12
Element Series
HC2206
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon
Supralon GlassFiber 12 micron (Beta 2000) Fluorocarbon 3in 7.62cm product photo

Supralon™ Lube and Hydraulic Elements, Removal Rating 12 μm, GlassFiber, Length 3 Inches

Product ID: HC2207FHS3Z
Unit of Measure
12/EA
Min Order Qty
12
Element Series
HC2207
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon

Documents

Datasheet

  • PERMAdur S

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes