Seitz® PERMAdur® S Support Sheets

Ideal for high performance and longevity 

The Seitz Permadur S Support Sheets afford stable, reusable precoat filtration in plate and frame presses. After filtration, the plate and frame are opened. The filter cake is removed, leaving the Seitz PERMAdur S filter sheet ready for the next run. Made of high-quality cellulose and polyolefin fibers, Seitz PERMAdur S support sheets' production is based on the latest technological and scientific achievements in-depth filter media. Get the support sheets with up to 30 percent longer service life over conventional sheets.  

  • Reduced appearance of swelling in the DE filter during filtration
  • May be removed from the filter intact without risk of damage or tearing
  • Retention of wet strength even with repeated hot sanitizations
  • Full traceability - Each individual filter sheet is laser etched with the sheet grade, batch number and production date. The packing label includes sheet grade, batch, identification number and a fork and glass symbol.

Order Products

Nominal OD (Metric)

4.67 cm

Athalon Glass Fiber 12 micron (Beta 2000) Ethylene Propylene 7in 17.78cm product photo

UE209AS07J

Product ID: UE209AS07J
Unit of Measure
16/EA
Min Order Qty
16
Element Series
UE209
Nominal Length (Imperial)
7 in
Seal Material
Ethylene Propylene
Athalon Glass Fiber 12 micron (Beta 2000) Nitrile 7in 17.78cm product photo

UE209AS07H ELEMENT

Product ID: UE209AS07H
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
7 in
Seal Material
Nitrile
Athalon Glass Fiber 12 micron (Beta 2000) Nitrile 3in 7.62cm product photo

Element 209AS03H SRT

Product ID: UE209AS03H
Unit of Measure
16/EA
Min Order Qty
16
Element Series
UE209
Nominal Length (Imperial)
3 in
Seal Material
Nitrile
Athalon Glass Fiber 12 micron (Beta 2000) Fluorocarbon 3in 7.62cm product photo

ELEMENT ULTIPLEAT SRT

Product ID: UE209AS03Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
3 in
Seal Material
Fluorocarbon
Athalon Glass Fiber 12 micron (Beta 2000) Fluorocarbon 7in 17.78cm product photo

ELEMENT 209AS07Z

Product ID: UE209AS07Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Filter Removal Rating
12 micron (Beta 2000)
Nominal Length (Imperial)
7 in
Seal Material
Fluorocarbon
Athalon Glass Fiber 7 micron (Beta 2000) Nitrile 7in 17.78cm product photo

Athalon Glass Fiber 7 micron (Beta 2000) Nitrile 7in 17.78cm

Product ID: UE209AN07H
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Nominal Length (Imperial)
7 in
Seal Material
Nitrile
Athalon Glass Fiber 7 micron (Beta 2000) Fluorocarbon 7in 17.78cm product photo

ELEMENT ULTIPLEAT SRT

Product ID: UE209AN07Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Filter Removal Rating
7 micron (Beta 2000)
Nominal Length (Imperial)
7 in
Seal Material
Fluorocarbon
Athalon Glass Fiber 25 micron (Beta 2000) Ethylene Propylene 7in 17.78cm product photo

UE209AT07J

Product ID: UE209AT07J
Unit of Measure
16/EA
Min Order Qty
16
Element Series
UE209
Nominal Length (Imperial)
7 in
Seal Material
Ethylene Propylene
Athalon Glass Fiber 5 micron (Beta 2000) Fluorocarbon 7in 17.78cm product photo

UE209AP07Z ELEMENT

Product ID: UE209AP07Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Filter Removal Rating
5 micron (Beta 2000)
Nominal Length (Imperial)
7 in
Seal Material
Fluorocarbon
Athalon Glass Fiber 25 micron (Beta 2000) Fluorocarbon 7in 17.78cm product photo

ELEMENT ULTIPLEAT SRT

Product ID: UE209AT07Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Nominal Length (Imperial)
7 in
Seal Material
Fluorocarbon
Athalon Glass Fiber 3 micron (Beta 2000) Fluorocarbon 7in 17.78cm product photo

SRT ELEMENT UE209AZ07Z

Product ID: UE209AZ07ZYT03
Unit of Measure
16/EA
Min Order Qty
16
Element Series
UE209
Nominal Length (Imperial)
7 in
Seal Material
Fluorocarbon
Athalon Glass Fiber 3 micron (Beta 2000) Fluorocarbon 7in 17.78cm product photo

UE209AZ07Z ELEMENT

Product ID: UE209AZ07Z
Unit of Measure
6/EA
Min Order Qty
6
Element Series
UE209
Nominal Length (Imperial)
7 in
Seal Material
Fluorocarbon

Documents

Datasheet

  • PERMAdur S

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Specifications

Food Contact Compliance 

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Materials of Construction

  • Main components: Celluloses, Polyolefin fibers
  • Components <3%: Resin

 

Characterization:

  • Mass per unit area g/m2 - 855
  • Thickness mm – 3.5
  • Ash %  < 1
  • Heavy metals* (ppm) < 50
  • Permeability L/m2/min at 1 bar 4370

 

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association. *According to recommendation XXXVI/1 of the BgW.

 

  • Exctractable ions soluble in 5% acetic acid mg/m2
  • CA 800
  • Fe 5
  • Al 15

 

Quality

Filter sheets produced in a controlled environment. Manufactured according to ISO 9001:2015 certified Quality Management System.

 

Suggested Operating Instructions

Handling during installation 

  1. Place sheet over support plate of the plate and frame filter
  2. For filters with manual tightening device: moisten filter sheets then tighten
  3. For filters with hydraulic tightening device: tighten up to filter pre-pressure of 30-35 bar (432-507 psi). Rinse the filter with warm water at ambient temperature in a forward flow direction with at a flow of at least 50 L/m2
  4. Control and adjust the filter to a pre-pressure of 30-35 bar (432-507 psi) and sterilize

 

Rinsing post filtration 

  1. Flush with water at a temperature of 50-55 °C (122-131 °F)
  2. Flow in the forward direction: should be at least nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: 10-15 minutes or until the rinse water is clear.

 

Hot water flushing 

  1. Water temperature: >85 °C (185 °F)
  2. Flow in the forward direction: minimal nominal filter output
  3. Counter pressure of 0.5 bar (7.25 psi)
  4. Duration: until a temperature of at least 85 °C (185 °F) is achieved on the outlet side. Allow the filter to stand for at least 30 minutes with hot water. Open the vent valve on the filter inlet side.

 

Steaming 

  1. Steam temperature: max 121 °C (250 °F), low-pressure steam
  2. Duration: 20 minutes