PRODUCT SPECIFICATIONS:
Materials
Media: Polypropylene with high-density polyethylene
O-ring seal: Fluorocarbon, nitrile, ethylene-propylene rubber
End caps: Glass-fiber-reinforced polypropylene
Dimensions (nominal)
Outside diameter: 152.4 mm (6 in)
Length:
- 508 mm (20 in)
- 1016 mm (40 in)
- 1524 mm (60 in)
Liquid Removal Ratings (µm)
Media grade |
Efficiency by particle count5 |
Y100 |
9.2 (99.9%) |
Y150 |
16.0 (99.9%) |
Y400 |
38.3 (99.9%) |
Y750 |
73.3 (99.5%) |
Y1000 |
>100.0 (90%) |
Liquid Flow Specifications
Media grade |
Pressure drop mbard/lpm (psid/gpm), water @ 20 °C (68 °F) 6 |
|
20-Inch |
40-Inch |
60-Inch |
Y100 |
1.13 (0.062) |
0.56 (0.031) |
0.3767 (0.0207) |
Y150 |
0.47 (0.026) |
0.24 (0.013) |
0.1567 (0.0087) |
Y400 |
0.09 (0.005) |
0.04 (0.0025) |
0.03 (0.0017) |
Y750 |
0.09 (0.005) |
0.04 (0.0025) |
0.03 (0.0017) |
Y1000 |
0.05 (0.003) |
0.03 (0.0015) |
0.0167 (0.001) |
kPa/lpm = 0.1000 mbard/lpm
5 Based on a modified ISO 16889 test procedure.
6 To determine pressure drop per flow rate for filters only, multiply this value by the total flow rate. (For liquids with a viscosity differing from water, multiply the pressure drop by the viscosity in centipoise.) To determine the system pressure drop, add this value to the pressure drop per flow rate value for the housing.
PERFORMANCE SPECIFICATIONS
Maximum operating temperature2
Maximum operating differential pressure3
- 2.9 bard @ 20 °C / 42 psid @ 68 °F
- 1.03 bard @ 65.5 °C / 15 psid @150 °F
Recommended differential pressure for changeout4
2 In compatible fluids that do not soften, swell, or adversely affect the performance of the filter or the materials of construction.
3 Recommendation is for inside-to-outside flow only.
4 Provided that the maximum differential pressure is not exceeded based on temperature limits defined above.