Medallion™ HP Series Liquid/Gas Coalescers

 

Pall’s Medallion™ HP line of liquid/gas coalescers is designed to meet the needs of the process industry, offering high performance and reduced operation and maintenance costs. Medallion coalescers can be used for many applications to enhance process performance.

Pall offers a full range of product options designed to meet various performance needs.

Order Products

Industries

Industrial Manufacturing

Product Type

Diagnostic and Monitoring Equipment

Electrical 4 - 20mA Transducer product photo

RCA222ZK2011 PRESSURE TRANSDUCER

Product ID: RCA222ZK2011
Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
0.8 bar
Maximum Pressure Range (Metric)
2 bar
Minimum Pressure Range (Metric)
0.5 bar
Seal Material
Viton
Upper Indication Point (Metric)
1.1 bar
See All Attributes
Electrical 4 - 20mA Transducer product photo

RCA222ZK4024 PRESSURE TRANSDUCER

Product ID: RCA222ZK4024
Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
1.8 bar
Maximum Pressure Range (Metric)
4 bar
Minimum Pressure Range (Metric)
1 bar
Seal Material
Viton
Upper Indication Point (Metric)
2.4 bar
See All Attributes
Electrical 4 - 20mA Transducer product photo

RCA222ZK8069 PRESSURE TRANSDUCER

Product ID: RCA222ZK8069
Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
4.8 bar
Maximum Pressure Range (Metric)
8 bar
Minimum Pressure Range (Metric)
2 bar
Seal Material
Viton
Upper Indication Point (Metric)
6.9 bar
See All Attributes
Electrical 4 - 20mA Transducer product photo

RCA222ZK4034 PRESSURE TRANSDUCER

Product ID: RCA222ZK4034
Unit of Measure
1/EA
Min Order Qty
1
Electrical Output
4-20 mA mA
Lower Indication Pressure (Metric)
2.4 bar
Maximum Pressure Range (Metric)
4 bar
Minimum Pressure Range (Metric)
1 bar
Seal Material
Viton
Upper Indication Point (Metric)
3.4 bar
See All Attributes
HCA132-24 ASSEMBLY SWITCH product photo

HCA132-24 ASSEMBLY SWITCH

Product ID: HCA132-24
Unit of Measure
1/EA
Min Order Qty
1
9004D370-25 GAUGE product photo

9004D370-25 GAUGE

Product ID: UK22049
Unit of Measure
1/EA
Min Order Qty
1
GAUGE 9004D370-34 product photo

GAUGE 9004D370-34

Product ID: HC9004D370-34
Unit of Measure
1/EA
Min Order Qty
1
HCA132-35 product photo

HCA132-35

Product ID: HCA132-35
Unit of Measure
1/EA
Min Order Qty
1
HH8630LL-35 Indicator product photo

HH8630LL-35 Indicator

Product ID: HH8630LL35
Unit of Measure
1/EA
Min Order Qty
1
Electrical Indicator with auto reset and AMP style connector product photo

INDICATOR RCA216CZ090ZX

Product ID: RCA216CZ090ZX
Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
2.4 bar
Seal Material
Viton
Switch Type
Normally Open
Electrical Indicator with auto reset and AMP style connector product photo

Electrical Indicator with auto reset and AMP style connector

Product ID: RCA216CZ091Z
Unit of Measure
1/EA
Min Order Qty
1
Indication Pressure (Metric)
3.4 bar
Seal Material
Viton
Switch Type
Normally Closed

Documents

Datasheet

  • Medallion™ HP Series Liquid/Gas Coalescers

    Select Language :

Description

Pall’s Medallion™ HP line of liquid/gas coalescers is designed to meet the needs of the process industry, offering high performance and reduced operation and maintenance costs. Medallion coalescers can be used for many applications to enhance process performance.

 

Pall offers a full range of product options designed to meet various performance needs.

 

Features, Advantages, and Benefits of the Pall Medallion Liquid/Gas Coalescers

 
Features Advantages Benefits
Medallion media pack
  • High liquid removal per unit area
  • Fewer elements needed
  • Minimized vessel diameter
  • Reduced need for an upstream bulk separator
  • Reduced capital and installation costs
High-capacity large-diameter element
  • Fewer elements needed for a given gas flow rate
  • Minimized vessel diameter
  • Reduced capital and installation costs
  • Smaller space required for installation
High-effective filtration area
  • Fewer element changeouts needed
  • The high solids removal efficiency
  • Lower operating and maintenance costs

High-efficiency media and equipment

  • Lower maintenance costs and availability

Applications

  • Inlet/Outlet Reciprocating Compressor
  • Turbine Protection
  • Inlet/Outlet Amine Contactor
  • Low and Ultra-low NOx Burner Protection
  • Inlet/Outlet Glycol Contactor
  • Gas Separation Membrane Protection
  • Mole Sieve Protection
  • Sales Gas
  • Mercury Removal Catalyst Protection
  • Transmission Pipeline Gas
  • Pipeline Metering / Compression Stations

Specifications

Materials of construction

Glass Microfiber Medium
A Style Compatible with most applications
  SOE P/N CS604LGT2H13
  DOE P/N CS604LGT2DH13
B Style Compatible with Amine and Ammonia gas
  SOE P/N CS604LGBT2H13
  DOE P/N CS604LGBT2DH13
End caps 300 series SS

Performance

Data

Liquids
  • 99.999% at 0.3 micron per DOP test
  • 1 ppb downstream liquids (CAGI)1
Solids  99.7% for particles >0.3 micron per NaCl test
Max Burst Pressure  50 psid (3.45 bard) 
Maximum operating temperatures
  • 180°F (82.2 °C) in gas service with no water present
  • 140°F (60.0 °C) in gas service with water present

 

1 Per the modified ANSI/CAGI-400-1999 test procedure

Type

Coalescers

Additional Information