Seitz® AKS4 Activated Carbon Sheets

Immobilized carbon filter media for general purpose carbon adsorption applications

Why go bulk powdered activated carbon (PAC) when you can go with Seitz AKS4 Activated Carbon Sheets? Developed to satisfy general purpose carbon adsorption applications in the food and beverage industry, the AKS4 Sheets include activated carbon within a cellulosic fibers matrix. Carbon-impregnated media with a homogeneous and consistent matrix means you can eliminate concerns over cleaning the process equipment and time and costs associated with carbon removal. Available in rectangular sheets. Other formats are available on request. 

  • High adsorption efficiency reduces overall processing time
  • Paper layer eliminates the requirement for downstream trap filtration
  • Good permeability with excellent filtrate quality
  • High economic efficiency and long service life
Seitz® AKS4 Activated Carbon Sheets

Product images are a representation of product family for illustration purposes only. Actual products may vary.

Order Products

Supracap™ 50 depth filter capsule with dual-layer media grade PDD2 (0.2-0.8 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDD2 (0.2-0.8 µm retention rating) and luer-lock connections

Product ID: SC050PDD2
Unit of Measure
1/EA
Min Order Qty
1
0.2-0.8 µm
Regenerated Cellulose
3 L
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with single-layer media grade SUPRA EK1P (0.2-0.5 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with single-layer media grade SUPRA EK1P (0.2-0.5 µm retention rating) and luer-lock connections

Product ID: SC050PEK1
Unit of Measure
1/EA
Min Order Qty
1
0.2-0.5 µm
Regenerated Cellulose
3 L
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with dual-layer media grade PDL3 (0.2-3 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDL3 (0.2-3 µm retention rating) and luer-lock connections

Product ID: SC050PDL3
Unit of Measure
1/EA
Min Order Qty
1
0.2-3 µm
Regenerated Cellulose
3 L
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with dual-layer media grade PDE2 (0.2-3.5 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with dual-layer media grade PDE2 (0.2-3.5 µm retention rating) and luer-lock connections

Product ID: SC050PDE2
Unit of Measure
1/EA
Min Order Qty
1
0.2-3.5 µm
Regenerated Cellulose
3 L
22 cm²
See All Attributes
Supracap™ 50 depth filter capsule with single-layer media grade EKMP (0.2-0.5 µm retention rating) and luer-lock connections product photo

Supracap™ 50 depth filter capsule with single-layer media grade EKMP (0.2-0.5 µm retention rating) and luer-lock connections

Product ID: SC050PEKM
Unit of Measure
1/EA
Min Order Qty
1
0.2-0.5 µm
Regenerated Cellulose
3 L
22 cm²
See All Attributes
Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, 1½ in. sanitary flange inlet and ½ in. hose barb outlet connections, pre-sterilized by gamma irradiation

Product ID: KA2DFLP16S
Unit of Measure
1/EA
Min Order Qty
1
0.2 µm
Polyvinylidene fluoride (PVDF)
Provided Pre-Sterilized by Gamma Irradiation
See All Attributes
Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, ¼-½ in. hose barb connections, suitable for gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 800 cm² EFA, ¼-½ in. hose barb connections, suitable for gamma irradiation

Product ID: KA2DFLP2G
Unit of Measure
1/EA
Min Order Qty
1
0.2 µm
Polyvinylidene fluoride (PVDF)
Suitable for Gamma Irradiation, Suitable for Autoclave
See All Attributes
Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1500 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation product photo

Fluorodyne® II DFL membrane in Kleenpak™ capsule, 0.2 µm sterilizing grade, 1500 cm² EFA, 1-1½ in. sanitary flange connections, suitable for gamma irradiation

Product ID: KA3DFLP1G
Unit of Measure
1/EA
Min Order Qty
1
0.2 µm
Polyvinylidene fluoride (PVDF)
Suitable for Gamma Irradiation, Suitable for Autoclave
See All Attributes
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, SOE flat closed end external 222 O-rings product photo
Unit of Measure
30/EA
Min Order Qty
30
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, EPDM, SOE fin end external 226 O-rings product photo
Unit of Measure
1/EA
Min Order Qty
1
0.2 µm
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, FEP encapsulated Fluorocarbon Elastomer Orings, SOE flat closed end external 222 O-rings product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, FEP encapsulated Fluorocarbon Elastomer Orings, SOE flat closed end external 222 O-rings

Product ID: PFT0210UFM3
Unit of Measure
1/EA
Min Order Qty
1
Removal Rating
0.2 µm
Membrane Material
Highly Asymetric Polysulfone
Industry-Specific Certification
General Use
Cartridge Length (Imperial)
10 in
Cartridge Length (Metric)
254 mm
Cartridge Length (Metric)
25.4 cm
See All Attributes
Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, silicone, DOE industrial product photo

Poly-Fine® II, Filter Cartridges, Removal Rating 0.2 μm, Highly Asymetric Polysulfone, Length 10 Inches, silicone, DOE industrial

Product ID: PFT0210US
Unit of Measure
1/EA
Min Order Qty
1
0.2 µm

Documents

Datasheet

  • Seitz AKS4 Series Depth Filter Sheets

    Select Language :

Instructions for Use

  • Seitz Sheets: Instructions

    Select Language :

Applications

  • Correction of off-color, flavor and odors in distilled spirits
  • Decolorization of sweetener and sugar syrups
  • Color correction in juice and beer applications
  • Gelatin decolorization and deodorization

Specifications

Food Contact Compliance

  • Please refer to the Pall website for a Declaration of Compliance to specific National Legislation and/or Regional Regulatory requirements for food contact use.

 

Main Constituents

  • Cellulose, powdered activated carbon, diatomaceous earth (DE, Kieselguhr)

 

Adsorption Capability

At an optimized flow rate, the probability of contact between the impurities and carbon particles is greater in carbon-impregnated sheets. This is due to process fluids more efficiently contacting carbon particles immobilized into a sheet matrix. Because of the sheet's depth (thickness), it is possible to consider the structure as being made up of a series of layers containing PAC. Having a depth of PAC and passing the fluid at an optimal flow rate through that depth enables maximum utilization of the carbon. Macro- and mesopores can generally be regarded as the highways into the carbon particle and are crucial for adsorption kinetics. Macropores are used for transport, and adsorption occurs in the meso- and micropores. Small molecules, such as methylene blue, which has a molecular weight of 319.86 Dalton, are mainly captured in micropores. Typically, over 20 g/m2 methylene blue is adsorbed.

 

Characterization

Sheet with
Protection Paper
Mass per Unit Area
g/m2
Thickness
mm
Ash
%
Water Permeability1 l/m2/min (gal/ft2/min)
No 1050 3.8 13 291 (7.2)
Yes 1050 3.8 13 100 (2.5)

These figures have been determined in accordance with in-house test methods and the methods of the Technical / Analytical Work Group within the European Depth Filtration Association.

 

Regeneration

Depending upon the application and the adsorbed contaminants' nature, AKS series filter sheets may be regenerated by rinsing with clean water in the forward direction. However, the achievable regeneration efficiency must be determined by monitoring filtrate quality.


Sterilization and Sanitization

Method Temperature °C (°F) Maximum Differential Pressure Bar (psi) Time2 Cycle
min
Steam 125 (257) 0.5 (7.2) 20
Hot Water 90 (194) 1 (14.5) 30

1The permeability was measured under test conditions with clean water at 20 °C (68 °F) and a Δp of 1 bar (14.5 psi).

2The actual time required may vary as a function of the process conditions.